Bioburden in health care centers: is the compliance with Portuguese legislation enough to prevent and control infection?

Use this identifier to reference this record.

Advisor(s)

Abstract(s)

This study intends to assess the bioburden in ten Portuguese health care centers (PHCC) with a multi-approach protocol using active (air sampling by impaction and impinger) and passive (surface swabs and air-conditioning filters) sampling methods, and compare the results with compliance levels of IAQ Portuguese legislation for the assessment of bioburden. The fungal burden in the PHCC was also characterized through molecular detection of toxigenic species, antifungal resistance and mycotoxins profile. Concerning legal compliance criteria for bacteriota the first criteria [indoor] + 350 CFU. m−3 < [outdoor] was not compiled in all PHCC analyzed. Regarding fungal load, 60% did not comply with the quantitative guideline (I/O < 1). Growth of four fungal genera (Chrysosporium, Cladosporium, Mucor, and Penicillium) was observed in HVAC filter samples collected from 6 out of 10 assessed PHCC when using azole-supplemented SDA media. Overall, Aspergillus/Penicillium/Paecilomyces levels were above the detection limits, except in one PHCC. The presence of mycotoxins was found both in air and HVAC filter samples. From the air samples analyzed, nine were contaminated (ng/ml) with 1–5 different mycotoxins within the same sample, whereas in HVAC filters, four samples contained 1 or 2 mycotoxins in the same filter. Overall, it was possible to conclude that Portuguese legislation is not enough to ensure IAQ in health care settings. The multi-approach sampling protocol used in this study allowed to unveil a more real scenario regarding exposure to bioburden. Detection of mycotoxins reinforces the relevance of studying mycotoxins in the clinical environment.

Description

EXPOsE – Establishing protocols to assess occupational exposure to microbiota in clinical settings. Project nº 23222 (02/SAICT/2016).

Keywords

Public health Environmental exposure Health care center Multi-approach sampling protocol Aspergillus Azole resistance Mycotoxins Project EXPOsE Project nº 23222 (02/SAICT/2016)

Citation

Viegas C, Monteiro A, Caetano LA, Carolino E, Gomes AQ, Viegas S, et al. Bioburden in health care centers: Is the compliance with Portuguese legislation enough to prevent and control infection? Build Environ. 2019;160:106226.

Research Projects

Organizational Units

Journal Issue

Publisher

Elsevier

Collections

Altmetrics