Avaliação da área avascular da fóvea: diferenças entre dois protocolos de aquisição

dc.contributor.authorAnacleto, Inês
dc.contributor.authorTarracha, Catarina
dc.contributor.authorPires, João Pedro
dc.contributor.authorSantos, Verónica
dc.contributor.authorVarandas, Teresa
dc.contributor.authorCamacho, Pedro
dc.contributor.authorPoças, Ilda Maria
dc.contributor.authorCarolino, Elisabete
dc.contributor.authorPereira, Bruno
dc.date.accessioned2024-04-10T12:12:43Z
dc.date.available2024-04-10T12:12:43Z
dc.date.issued2023-11
dc.descriptionEste projeto foi parcialmente suportado pelo projeto IDI&CA IPL/2021/DiffMeDiME_ESTeSL do H&TRC – Health & Technology Research Center, ESTeSL – Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de Lisboa e Instituto de Retina de Lisboa (IRL).pt_PT
dc.description.abstractO OCT-A é um exame que permite a visualização da vascularização da retina e da coroide, assim como a visualização tridimensional dos plexos vasculares em diferentes profundidades, fornecendo informação funcional sobre o fluxo sanguíneo nos vasos, zonas de não perfusão ou neovascularização. A zona avascular da fóvea (FAZ) corresponde a uma zona desprovida de capilares na região foveolar e pode ser detetada e medida com recurso ao OCT-A. Ao realizar o exame é possível optar por dois métodos com diferente resolução e tempo de aquisição, pelo que é importante avaliar se as medições efetuadas são comparáveis entre os dois métodos. O objetivo do estudo foi verificar se existem diferenças na medição da área avascular da fóvea entre dois protocolos diferentes de aquisição de OCT-A. O estudo realizado foi um estudo caso-controlo transversal. A amostra foi composta por 26 participantes com diabetes mellitus. O instrumento utilizado foi o SD-OCT HRA+OCT SPECTRALIS Heidelberg Engineering. A avaliação dos participantes foi constituída pela recolha de mapas de OCT-A de 10º x 10º (HR) e 20º x 20º (HS). Os mapas foram medidos manualmente por dois observadores, sendo que cada um fez duas medições da zona avascular da fóvea de cada mapa (HS e HR) em cada plexo (superficial e profundo). Com recurso ao programa SPSS efetuou-se a análise estatística das amostras. Não se verificaram diferenças estatisticamente significativas entre as diferentes medições, podendo-se assim afirmar que a avaliação com os dois protocolos é repetível e reprodutível, existindo uma boa concordância entre os métodos. No entanto, a utilização de ambos os plexos retinianos em conjunto para avaliação da área avascular da fóvea poderá ser mais adequada.pt_PT
dc.description.abstractABSTRACT - OCT-A is an exam that allows visualization of the retinal and choroidal vascularization as well as the three-dimensional visualization of the vascular plexuses at different depths, providing functional information about the blood flow in the vessels, and areas of non-perfusion or neovascularization. The foveal avascular zone corresponds to an area deprived of capillaries in the foveolar region that can be detected and measured using OCT-A. When performing the exam, it is possible to choose between two methods with different resolution and acquisition times, so it is important to assess whether the measurements are comparable between methods. The objective of this study was to see if there are differences in the measurement of the foveal avascular zone between two different OCT-A scanning protocols. The conducted study was a case-control cross-sectional study. The sample consisted of 26 participants with diabetes mellitus. The instrument used was the SD-OCT HRA+OCT SPECTRALIS Heidelberg Engineering. The patient assessment consisted of collecting 10° x 10° high-resolution and 20° x 20° high-speed OCT-A scans. These were manually measured by two observers, who each took two measurements of the foveal avascular zone of each scan (high-speed and high-resolution) in each complex (superficial and deep). Statistical analysis was performed using the SPSS program. There were no statistically significant differences between the different measurements, and it can be stated that the evaluation of the two protocols is repeatable and reproducible, with good agreement between the methods. However, the use of both retinal plexuses together to evaluate the foveal avascular zone may be more appropriate.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationAnacleto I, Tarracha C, Camacho P, Poças IM, Carolino E, Pereira B, et al. Avaliação da área avascular da fóvea: diferenças entre dois protocolos de aquisição. Saúde & Tecnologia. 2023;(29):e603.pt_PT
dc.identifier.doi10.25758/set.603pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/17293
dc.language.isoporpt_PT
dc.peerreviewedyespt_PT
dc.publisherInstituto Politécnico de Lisboa, Escola Superior de Tecnologia da Saúde de Lisboapt_PT
dc.relationIDI&CA IPL/2021/DiffMeDiME_ESTeSLpt_PT
dc.relation.publisherversionhttps://journals.ipl.pt/stecnologia/article/view/603pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectÁrea avascular da fóveapt_PT
dc.subjectAngiografia por tomografia de coerência óticapt_PT
dc.subjectPlexo vascular superficialpt_PT
dc.subjectPlexo vascular profundopt_PT
dc.subjectRetinopatia diabéticapt_PT
dc.subjectOrtópticapt_PT
dc.subjectFoveal avascular zonept_PT
dc.subjectOptical coherence tomography angiographypt_PT
dc.subjectSuperficial vascular complexpt_PT
dc.subjectDeep vascular complexpt_PT
dc.subjectDiabetic retinopathypt_PT
dc.subjectOrthopticspt_PT
dc.subjectIDI&CA IPL/2021/DiffMeDiME_ESTeSLpt_PT
dc.titleAvaliação da área avascular da fóvea: diferenças entre dois protocolos de aquisiçãopt_PT
dc.title.alternativeFoveal avascular zone: differences between two different acquisition protocolspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue29pt_PT
oaire.citation.startPagee603pt_PT
oaire.citation.titleSaúde & Tecnologiapt_PT
person.familyNameCamacho
person.familyNamePoças
person.familyNameCarolino
person.givenNamePedro
person.givenNameIlda Maria
person.givenNameElisabete
person.identifier.ciencia-id271F-B4E1-014E
person.identifier.ciencia-id1E1A-86A4-BC50
person.identifier.ciencia-id1216-EFA3-1E0F
person.identifier.orcid0000-0002-2986-5652
person.identifier.orcid0000-0002-1695-3231
person.identifier.orcid0000-0003-4165-7052
person.identifier.ridF-1012-2015
person.identifier.scopus-author-id25821697000
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationc41e9c52-157e-4375-8005-b609cfc374e7
relation.isAuthorOfPublicationced35a9f-848a-49c9-91dc-f60f679f149f
relation.isAuthorOfPublication77930d39-ed34-44dc-a4a6-9bf833e5e688
relation.isAuthorOfPublication.latestForDiscoveryced35a9f-848a-49c9-91dc-f60f679f149f

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Avaliação da área avascular da fóvea_diferenças entre dois protocolos de aquisição.pdf
Size:
911.22 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections