Repository logo
 
Publication

Value of a lower limb immobilization device for SPECT/CT image fusion optimization

dc.contributor.authorMachado, Joana do Mar
dc.contributor.authorMonteiro, Marina S.
dc.contributor.authorVieira, Victor Fernandes
dc.contributor.authorCollinot, Jean-Aybert
dc.contributor.authorPrior, John O.
dc.contributor.authorVieira, Lina
dc.contributor.authorJorge, José
dc.date.accessioned2015-08-13T15:21:22Z
dc.date.available2015-08-13T15:21:22Z
dc.date.issued2015-06
dc.description.abstractThe foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.por
dc.identifier.citationMachado JM, Monteiro MS, Vieira VF, Collinot JA, Prior JO, Vieira L, et al. Value of a lower limb immobilization device for SPECT/CT image fusion optimization. J Nucl Med Technol. 2015;43(2):98-102.por
dc.identifier.doi10.2967/jnmt.114.145771
dc.identifier.urihttp://hdl.handle.net/10400.21/4747
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSociety of Nuclear Medicine and Molecular Imagingpor
dc.relation.publisherversionhttp://tech.snmjournals.org/content/43/2/98.longpor
dc.subjectNuclear medicinepor
dc.subjectSPECT/CTpor
dc.subjectMisalignmentpor
dc.subjectLower-limbpor
dc.subjectPatient-motionpor
dc.titleValue of a lower limb immobilization device for SPECT/CT image fusion optimizationpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage102por
oaire.citation.startPage98por
oaire.citation.titleJournal of Nuclear Medicine and Technologypor
oaire.citation.volume43por
rcaap.rightsopenAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Value of a lower limb immobilization device for SPECT_CT image fusion optimization.pdf
Size:
656.42 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections