Repository logo
 
Publication

Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool

dc.contributor.authorLeote, Joao
dc.contributor.authorLoução, Ricardo
dc.contributor.authorAguiar, Madalena
dc.contributor.authorTavares, Mariana
dc.contributor.authorFerreira, Paloma
dc.contributor.authorMuxagata, Tiago
dc.contributor.authorGuerreiro, Diana
dc.contributor.authorDias, Hermínia Brites
dc.contributor.authorBacariza, Jacobo
dc.contributor.authorGonzalez, Filipe
dc.date.accessioned2024-02-19T11:34:56Z
dc.date.available2024-02-19T11:34:56Z
dc.date.issued2024-06
dc.description.abstractQuantitative approaches to improve lung ultrasound (LUS) vertical artifacts (VA) interpretation using total signal intensity (ITOT) are not widely available for clinical practice. In this study, we aimed to i) develop a mathematical algorithm to extract ITOT as a post-hoc LUS analysis and ii) confirm ITOT utility by conducting laboratory VA research using an in vitro model with different acoustic channels. The ITOT was extracted from static and conventional LUS imaging recorded from in vitro models after varying the amount of water content or the pores size of the phantom, compared to a control condition. The defined algorithm was able to calculate the ITOT from all phantoms. Mean ITOT showed statistically significantly different values across phantom categories. We demonstrate that ITOT may be able to differentiate the in vitro acoustic channels formed by increased water content from those with small size pores. However, the utility of this semi-quantitative tool in clinical practice or other LUS imaging data sets remains unclear.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationLeote J, Aguiar M, Tavares M, Ferreira P, Muxagata T, Guerreiro D, Dias H, et al. Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool. WFUMB Ultrasound Open. 2024;2(1):100035.pt_PT
dc.identifier.doi10.1016/j.wfumbo.2024.100035pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/17126
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S294966832400003Xpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectLung ultrasoundpt_PT
dc.subjectVertical artifactspt_PT
dc.subjectTotal intensitypt_PT
dc.subjectSemi-quantitativept_PT
dc.titleTotal signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative toolpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue1pt_PT
oaire.citation.startPage100035pt_PT
oaire.citation.titleWFUMB Ultrasound Openpt_PT
oaire.citation.volume2pt_PT
person.familyNameDias
person.givenNameMaria Hermínia Monteiro Brites
person.identifier.ciencia-idE211-FB1B-04E3
person.identifier.orcid0000-0003-1257-8734
person.identifier.ridAFL-8310-2022
person.identifier.scopus-author-id55671930200
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationb7b7e7d9-83b2-4d63-9176-4ed73cf6b939
relation.isAuthorOfPublication.latestForDiscoveryb7b7e7d9-83b2-4d63-9176-4ed73cf6b939

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Total signal intensity of ultrasound laboratory vertical artifacts_a semi-quantitative tool.pdf
Size:
2.38 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections