Logo do repositório
 
Publicação

Assessment of influential operational parameters in the mitigation of CO2, emissions in a power plant: case study in Portugal

authorProfile.emailbiblioteca@isel.pt
datacite.subject.fosEngenharia e Tecnologia::Engenharia Mecânica
dc.contributor.authorBalanuta, Vítor
dc.contributor.authorBaptista, Patrícia
dc.contributor.authorCarreira, Fernando
dc.contributor.authorDuarte, Gonçalo O.
dc.contributor.authorCasaca, Cláudia S. S. L.
dc.date.accessioned2026-05-04T10:52:22Z
dc.date.available2026-05-04T10:52:22Z
dc.date.issued2024-09-06
dc.descriptionThis research was funded by Polytechnic University of Lisbon grant number IPL/IDI&CA2023/GEErVap_ISEL
dc.description.abstractThe European decarbonization goals and requirement for energy independence are mostly relying on intermittent renewable energy sources for electrification. A numerical model was developed to simulate the operation of a steam generator, allowing a study of the potential impacts of retrofitting existing coal-fired power plants to operate with biomass or coal–biomass mixtures on combustion parameters and CO2 emissions. The results obtained using the operational parameters of the Sines power plant indicate that a mixture of 25% coal and 75% pine sawdust allow operation at λ = 1.8, demonstrating that a small amount of coal allows operation near the coal combustion parameters (λ = 1.9). These conditions have the drawback of a reduction of 8.7% in adiabatic flame temperature but a significant reduction of 57.5% in CO2 emissions, considering the biomass as carbon-neutral.eng
dc.description.sponsorshipIPL/IDI&CA2023/GEErVap_ISEL - Instituto Politécnico de Lisboa
dc.identifier.citationBalanuta, V., Baptista, P., Carreira, F., Duarte, O., & Casaca, C. (2024). Assessment of influential operational parameters in the mitigation of CO2, emissions in a power plant: case study in Portugal. Clean Technologies, 6(3), 1169-1180. https://doi.org/10.3390/cleantechnol6030057
dc.identifier.doi10.3390/cleantechnol6030057
dc.identifier.eissn2571-8797
dc.identifier.urihttp://hdl.handle.net/10400.21/22847
dc.language.isoeng
dc.peerreviewedyes
dc.publisherMDPI
dc.relation.hasversionhttps://www.mdpi.com/2571-8797/6/3/57
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectGreenhouse gas emissions
dc.subjectBiomass
dc.subjectThermal power plant
dc.subjectRetrofitting
dc.subjectDecarbonization
dc.subjectIPL/IDI&CA2023/GEErVap_ISEL
dc.titleAssessment of influential operational parameters in the mitigation of CO2, emissions in a power plant: case study in Portugaleng
dc.typeresearch article
dspace.entity.typePublication
oaire.citation.endPage1180
oaire.citation.issue3
oaire.citation.startPage1169
oaire.citation.titleClean Technologies
oaire.citation.volume6
oaire.versionhttp://purl.org/coar/version/c_be7fb7dd8ff6fe43

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
Assessment_CSSLCasaca.pdf
Tamanho:
1.63 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
4.03 KB
Formato:
Item-specific license agreed upon to submission
Descrição: