Repository logo
 
Publication

Settled dust assessment in clinical environment: useful for the evaluation of a wider bioburden spectrum

dc.contributor.authorViegas, Carla
dc.contributor.authorAlmeida, Beatriz
dc.contributor.authorMonteiro, Ana
dc.contributor.authorPaciência, Inês
dc.contributor.authorRufo, João Cavaleiro
dc.contributor.authorCarolino, Elisabete
dc.contributor.authorGomes, Anita Quintal
dc.contributor.authorTwarużek, Magdalena
dc.contributor.authorKosicki, Robert
dc.contributor.authorMarchand, Geneviéve
dc.contributor.authorAranha Caetano, Liliana
dc.contributor.authorViegas, Susana
dc.date.accessioned2019-06-26T12:11:36Z
dc.date.available2019-06-26T12:11:36Z
dc.date.issued2021-02
dc.descriptionProject EXPOsE – Establishing protocols to assess occupational exposure to microbiota in clinical settings. Project nº 23222 (02/SAICT/2016).pt_PT
dc.description.abstractThe collection and analysis of settled dust samples from indoor environments has become one of several environmental sampling methods used to assess bioburden indoors. The aim of the study was to characterize the bioburden in vacuumed settled dust from 10 Primary Health Care Centers by culture-based and molecular methods. Results for bacterial load ranged from 1 to 12 CFU.g−1 of dust and Gram-negative bacteria ranged between 1 to 344 CFU.g−1 of dust. Fungal load ranged from 0 CFU.g−1 of dust to uncountable. Aspergillus section Fumigati was detected in 4 sampling sites where culture base-methods could not identify this section. Mucorales (Rhizopus sp.) was observed on 1 mg/L voriconazole. Three out of 10 settled dust samples were contaminated by mycotoxins. Settled dust sampling coupled with air sampling in a routine way might provide useful information about bioburden exposure.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationViegas C, Monteiro A, Carolino E, Gomes AQ, Caetano LA, Viegas S, et al. Settled dust assessment in clinical environment: useful for the evaluation of a wider bioburden spectrum. Int J Environ Health Res. 2021;31(2):160-78.pt_PT
dc.identifier.doi10.1080/09603123.2019.1634799pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/10210
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherTaylor & Francispt_PT
dc.relationProject EXPOsE – Establishing protocols to assess occupational exposure to microbiota in clinical settingspt_PT
dc.relationProject nº 23222 (02/SAICT/2016)pt_PT
dc.relation.publisherversionhttps://www.tandfonline.com/doi/full/10.1080/09603123.2019.1634799pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectEnvironmental exposurept_PT
dc.subjectExposure assessmentpt_PT
dc.subjectSettled dustpt_PT
dc.subjectClinical environmentpt_PT
dc.subjectBioburdenpt_PT
dc.subjectMycotoxinspt_PT
dc.subjectProject EXPOsEpt_PT
dc.subjectProject nº 23222 (02/SAICT/2016)pt_PT
dc.titleSettled dust assessment in clinical environment: useful for the evaluation of a wider bioburden spectrumpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage19pt_PT
oaire.citation.endPage178pt_PT
oaire.citation.issue2pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.startPage160pt_PT
oaire.citation.titleInternational Journal of Environmental Health Researchpt_PT
oaire.citation.volume31pt_PT
person.familyNameViegas
person.familyNameCarolino
person.familyNameAranha Caetano
person.familyNameViegas
person.givenNameCarla
person.givenNameElisabete
person.givenNameLiliana
person.givenNameSusana
person.identifier248817
person.identifier.ciencia-idEE1E-C639-D70F
person.identifier.ciencia-id1216-EFA3-1E0F
person.identifier.ciencia-id9716-9DAC-532A
person.identifier.ciencia-idA919-7318-63DC
person.identifier.orcid0000-0002-1545-6479
person.identifier.orcid0000-0003-4165-7052
person.identifier.orcid0000-0003-1496-2609
person.identifier.orcid0000-0003-1015-8760
person.identifier.ridB-7217-2013
person.identifier.ridF-1012-2015
person.identifier.ridI-4053-2012
person.identifier.scopus-author-id55443609700
person.identifier.scopus-author-id25821697000
person.identifier.scopus-author-id35270591500
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationb5fa5da4-50c3-4b88-ae20-1bc63cb485f7
relation.isAuthorOfPublication77930d39-ed34-44dc-a4a6-9bf833e5e688
relation.isAuthorOfPublication6517c656-f913-4f54-8682-77c2856c9e4c
relation.isAuthorOfPublication13115332-43f7-4048-a8a5-2f2b855a8c92
relation.isAuthorOfPublication.latestForDiscovery13115332-43f7-4048-a8a5-2f2b855a8c92

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Settled dust assessment in clinical environment_useful for the evaluation of a wider bioburden spectrum.pdf
Size:
2.09 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections