Repository logo
 
Publication

Dosimetric effect by shallow air cavities in high energy electron beams

dc.contributor.authorZarza-Moreno, M.
dc.contributor.authorCarreira, P.
dc.contributor.authorMadureira, L.
dc.contributor.authorMiras del Rio, H.
dc.contributor.authorSalguero, F. J.
dc.contributor.authorLeal, A.
dc.contributor.authorTeixeira, Nuno
dc.contributor.authorJesus, A. P.
dc.contributor.authorMora, G.
dc.date.accessioned2013-12-10T17:31:05Z
dc.date.available2013-12-10T17:31:05Z
dc.date.issued2014-03
dc.description.abstractThis study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam algorithm and Gafchromic EBT2 films. A home-PMMA phantom with the same geometry as the simulated one was specifically constructed for the measurements. Our results indicate that the presence of the cavity causes an increase (up to 70%) of the dose maximum value as well as a shift forward of the position of the depthedose curve, compared to the homogeneous one. Pronounced dose discontinuities in the regions close to the lateral cavity edges are observed. The shape and magnitude of these discontinuities change with the dimension of the cavity. It is also found that the cavity effect is more pronounced (6%) for the 12 MeV electron beam and the presence of cavities with large thickness and small area introduces more significant variations (up to 70%) on the depthedose curves. Overall, the Gafchromic EBT2 film measurements were found in agreement within 3% with Monte Carlo calculations and predict well the fine details of the dosimetric change near the cavity interface. The Pencil Beam calculations underestimate the dose up to 40% compared to Monte Carlo simulations; in particular for the largest cavity thickness (2.8 cm).por
dc.identifier.citationZarza-Moreno M, Carreira P, Madureira L, Miras del Rio H, Salguero FJ, Leal A, Teixeira N, el al. Dosimetric effect by shallow air cavities in high energy electron beams. Phys Med. 2014;30(2):234-41.por
dc.identifier.issn1120-1797
dc.identifier.urihttp://hdl.handle.net/10400.21/2985
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S1120179713002366por
dc.subjectPhysicspor
dc.subjectAir cavitypor
dc.subjectEBT2 Gafchromic filmpor
dc.subjectElectron beampor
dc.subjectMonte Carlo algorithmspor
dc.subjectPencil beam algorithmspor
dc.titleDosimetric effect by shallow air cavities in high energy electron beamspor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage241
oaire.citation.startPage234
oaire.citation.titlePhysica Medicapor
oaire.citation.volume30
rcaap.rightsopenAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Dosimetric effect by shallow air cavities in high energy electron beams.pdf
Size:
1.81 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections