The influence of number of counts in the myocardium in the determination of reproducible functional parameters in gated-SPECT studies simulated with GATE
dc.contributor.author | Vieira, Lina | |
dc.contributor.author | Costa, Durval C. | |
dc.contributor.author | Almeida, Pedro | |
dc.date.accessioned | 2015-08-17T11:22:03Z | |
dc.date.available | 2015-08-17T11:22:03Z | |
dc.date.issued | 2015-07 | |
dc.description.abstract | Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types. | por |
dc.identifier.citation | Vieira L, Costa DC, Almeida P. The influence of number of counts in the myocardium in the determination of reproducible functional parameters in gated-SPECT studies simulated with GATE. Rev Esp Med Nucl Imagen Mol. 2015;34(6):339-44. | por |
dc.identifier.doi | 10.1016/j.remn.2015.04.005 | |
dc.identifier.uri | http://hdl.handle.net/10400.21/4763 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Elsevier | por |
dc.relation.publisherversion | http://www.sciencedirect.com/science/article/pii/S2253654X15000578 | por |
dc.subject | Nuclear medicine | por |
dc.subject | Functional parameters | por |
dc.subject | GATE | por |
dc.subject | Gated-SPECT | por |
dc.subject | NCAT | por |
dc.subject | Number of counts | por |
dc.subject | Myocardium | por |
dc.title | The influence of number of counts in the myocardium in the determination of reproducible functional parameters in gated-SPECT studies simulated with GATE | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.title | Revista Española de Medicina Nuclear e Imagen Molecular | por |
rcaap.rights | restrictedAccess | por |
rcaap.type | article | por |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- The influence of number of counts in the myocardium in thedetermination of reproducible functional parameters.pdf
- Size:
- 452.56 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: