Publication
Instrumented 6-minutes walk test, an approach to improve the traditional test
dc.contributor.author | Galán-Mercant, Alejandro | |
dc.contributor.author | Tomás, Maria Teresa | |
dc.contributor.author | Fernandes, Beatriz | |
dc.date.accessioned | 2017-12-19T12:55:36Z | |
dc.date.available | 2017-12-19T12:55:36Z | |
dc.date.issued | 2016-10 | |
dc.description.abstract | Introduction: Exercise testing is frequently used to assist clinicians in assessing prognosis and evaluating response to treatment. The 6-min walk test is a standardized test of functional exercise capacity. Objectives: The aim of the present study was to identify and describe the anthropometric characteristics, gait velocity and instrumented 6-min walk test with kinematics parameters from the inertial sensor during the test in a Portuguese population of subjects over 65 years. Methods: They were measured variables related to anthropometrics, the 6-min walk test and kinematic variables in the 6-min walk test related to accelerations and angular velocity. Results: The results were; six minutes walk (359,26 ± 107.49 meters), initial heart rate (72,95 ± 7,74BPM), final initial heart rate (80,58 ± 13,86 BPM), initial systolic blood pressure (148,42 ± 21,25 mmHg), final systolic blood pressure (164,26 ± 24,49 mmHg), initial diastolic blood pressure (75,63 ± 11,04 mmHg), final diastolic blood pressure (77,00 ± 9,52 mmHg), gait velocity (1,04 ± 0,37 m/s), max rotation rate X (1,05 ± 0,36 rad/s), min rotation rate X (−0,82 ± 0,33 rad/s), max rotation rate Y (2,63 ± 0,96 rad/s), min rotation rate Y (−1,69 ± 0,81 rad/s), max rotation rate Z (1,03 ± 0,33 rad/s), min rotation rate Z (−1,12 ± 0,38 rad/s), max acceleration X (0,77 ± 0,37 m/s2), min acceleration X (−0,91 ± 0,44 m/s2), max acceleration Y (0,53 ± 0,23 m/s2), min acceleration Y (−1,25 ± 0,70 m/s2), max acceleration Z (0,49 ± 0,14 m/s2), min acceleration Z (−0,96 ± 0,34 m/s2). Conclusions: The only one outcome in 6-min walk the test (total distance in meters), could be complemented with inertial sensor information. This new complement could be interesting in order to understand other dimensions in the 6-min walk or identify changes in function and results in the test after a program to improve physical fitness. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Galán-Mercant A, Tomás MT, Fernandes B. Instrumented 6-minutes walk test, an approach to improve the traditional test. In: 12th International Congress of the European Union Geriatric Medicine Society, Lisboa Congress Center (Portugal), 5-7 October 2016. Eur Geriatr Med. 2016;7 Suppl 1:S119. | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.21/7730 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Elsevier | pt_PT |
dc.relation.publisherversion | http://www.europeangeriaticmedicine.com/article/S1878-7649(16)30149-8/fulltext | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_PT |
dc.subject | Physiotherapy | pt_PT |
dc.subject | Rehabilitation | pt_PT |
dc.subject | 6-minutes walk test | pt_PT |
dc.subject | Functional exercise | pt_PT |
dc.subject | Physical fitness | pt_PT |
dc.subject | Elderly | pt_PT |
dc.title | Instrumented 6-minutes walk test, an approach to improve the traditional test | pt_PT |
dc.type | conference object | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 119 | pt_PT |
oaire.citation.issue | Suppl 1 | pt_PT |
oaire.citation.startPage | 119 | pt_PT |
oaire.citation.title | European Geriatric Medicine | pt_PT |
oaire.citation.volume | 7 | pt_PT |
person.familyName | Tomás | |
person.givenName | Maria Teresa | |
person.identifier | 438585 | |
person.identifier.ciencia-id | 3010-19D6-C7A5 | |
person.identifier.orcid | 0000-0003-0491-8903 | |
person.identifier.rid | N-1940-2013 | |
person.identifier.scopus-author-id | 36700434200 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | conferenceObject | pt_PT |
relation.isAuthorOfPublication | 64ad74a4-4cd4-426e-a1ee-2ec846fdc6dd | |
relation.isAuthorOfPublication.latestForDiscovery | 64ad74a4-4cd4-426e-a1ee-2ec846fdc6dd |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Instrumented 6-minutes walk test, an approach to improve the traditional test.pdf
- Size:
- 2.51 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: