dc.date.issued2018
dc.description.abstractSignificant improvements have been made in Positron Emission Tomography (PET) to enhance the image quality, namely, the development of time-of-flight (TOF) technology. This technique is useful to localize the emission point of the beta plus-emitter (β+) radiopharmaceutical inside the body, allowing better lesion contrast and leading to a short scan time. The main goal of this study is to investigate the shortest acquisition time without compromising the image quality in both a NEMA body phantom and patients, using a TOF PET/Computed Tomography (PET/CT) scanner and the radionuclide Gallium-68 (68Ga). Image quality parameters and quantification in terms of standardized uptake value (SUV) were acquired. A time between 45 and 60 s per bed position is proposed for future clinical practices.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationOliveira J, Parafita R, Branco S. Minimisation of acquisition time in a TOF PET/CT scanner without compromising image quality. In: Tavares JM, Natal Jorge R, editors. VipIMAGE 2017: proceedings of the VI ECCOMAS Thematic Conference on Computational Vision and Medical Image Processing Porto, Portugal, October 18-20, 2017. p. 27-42. Cham: Springer; 2018.pt_PT
dc.identifier.doi10.1007/978-3-319-68195-5_4pt_PT
dc.identifier.isbn978-3-319-68195-5
dc.identifier.urihttp://hdl.handle.net/10400.21/7708
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSpringer Publishing Companypt_PT
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007/978-3-319-68195-5_4?no-access=truept_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectPET/CTpt_PT
dc.subjectTOFpt_PT
dc.subject68Gapt_PT
dc.subjectAcquisition timept_PT
dc.subjectImage qualitypt_PT
dc.titleMinimisation of acquisition time in a TOF PET/CT scanner without compromising image qualitypt_PT
dc.typebook part
dspace.entity.typePublication
oaire.citation.endPage42pt_PT
oaire.citation.startPage27pt_PT
rcaap.rightsrestrictedAccesspt_PT
rcaap.typebookPartpt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Minimisation of acquisition time in a TOF PET_CT scanner without compromising image quality.pdf
Size:
258.69 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: