Publication
Efeito da utilização da técnica de SGRT (Surface Guided Radiation Therapy) na redução dos erros inter e intra fração em tratamentos SBRT (Stereotatic Body Radiation Therapy) do pulmão
dc.contributor.advisor | Eiras, Margarida | pt_PT |
dc.contributor.advisor | Pimentel, Nuno | pt_PT |
dc.contributor.author | Gomes, Nicolle Cadinha | |
dc.date.accessioned | 2024-04-22T10:52:48Z | |
dc.date.available | 2024-04-22T10:52:48Z | |
dc.date.issued | 2023 | |
dc.description | Mestrado em Gestão e Avaliação de Tecnologias em Saúde | pt_PT |
dc.description.abstract | Introdução: Os doentes com cancro de pulmão tratados com Stereotactic Body Radiation Therapy exigem rigor no posicionamento e correspondência dos volumes alvo e órgãos de risco devido ao uso de doses de radiação elevada, com margens estreitas. Acresce considerar o ciclo respiratório, que por implicar movimento acarreta incertezas geométricas e dosimétricas. Com a técnica de Surface Guided Radiation Therapy é possível, sem o recurso a radiação ionizante, monitorizar em tempo real a posição do doente resultando potencialmente na minimização de erros interfração e intrafração. Objetivo: Analisar o efeito da utilização de um sistema de Surface Guided Radiation Therapy na diminuição de erros e aumento da segurança do doente. Metodologia: Foram elaborados dois artigos científicos com base em duas abordagens metodológicas distintas. O primeiro artigo corresponde a uma revisão sistemática da literatura que procura reunir a evidência existente sobre o tema, e o segundo, um estudo investigacional que pretende avaliar, em contexto clínico o contributo de um sistema de Surface Guided Radiation Therapy na redução de erros e aumento de segurança para o doente. Resultados e Discussão: Apesar da escassez de literatura que fundamenta esta temática, os resultados iniciais confirmam o benefício da utilização de Surface Guided Radiation Therapy. Verificou-se que os principais fatores que levam à existência dos erros, sobretudo intrafração foram detetados antecipadamente e, passíveis de serem corrigidos, contribuindo para uma maior segurança no tratamento do doente. Conclusão: A implementação de um sistema de Surface Guided Radiation Therapy, ao melhorar a precisão do posicionamento, ao controlar o movimento intrafração, torna possível um tratamento com mais segurança (menor toxicidade) e com maior qualidade (precisão). | pt_PT |
dc.description.abstract | ABSTRACT - Introduction: Lung cancer patients treated with Stereotactic Body Radiation Therapy, due to higher doses of radiation and strict treatment margins, require greater rigor in patient positioning and correspondence of treatment volumes and organs at risk. It is necessary to consider the respiratory cycle, which causes movement and therefore entails geometric and dosimetric uncertainties. By using a Surface Guided Radiation Therapy system, it is possible, without the use of ionizing radiation, to monitor the patient’s position, in real-time, reducing inter and intra-fraction errors. Objective: Analyse the effect of using a Surface Guided Radiation Therapy system in reducing errors and increasing patient safety. Methods: Two scientific studies were developed based on two different methodological approaches. The first article is a systematic review of the literature that aims to summarize the current evidence on this subject. The second article is an experimental study that analyses the contribution of the use of a Surface Guided Radiation Therapy system in reducing errors and increasing patient safety. Results and Discussion: There is a lack of literature on this subject, however, preliminary results support the use of a Surface Guided Radiation Therapy system. With the experimental study, it was possible to verify that the factors that lead to the existence of errors, especially intrafraction ones, were detected in advance and could be corrected, thus contributing to greater safety in the treatment of the patients. Conclusion: With the implementation of a Surface Guides Radiation Therapy system, by improving positioning accuracy, and controlling intrafraction motion, it is possible to make treatments safer and with higher quality. | pt_PT |
dc.description.version | N/A | pt_PT |
dc.identifier.citation | Gomes NC. Efeito da utilização da técnica de SGRT (Surface Guided Radiation Therapy) na redução dos erros inter e intra fração em tratamentos SBRT (Stereotatic Body Radiation Therapy) do pulmão [dissertation]. Lisboa: Escola Superior de Tecnologia da Saúde de Lisboa/Instituto Politécnico de Lisboa; Escola Superior de Saúde da Universidade do Algarve; 2023. | pt_PT |
dc.identifier.tid | 203431405 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.21/17350 | |
dc.language.iso | por | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Instituto Politécnico de Lisboa, Escola Superior de Tecnologia da Saúde de Lisboa | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_PT |
dc.subject | Radioterapia | pt_PT |
dc.subject | Stereotactic body radiation therapy | pt_PT |
dc.subject | SBRT | pt_PT |
dc.subject | Surface guided radiation therapy | pt_PT |
dc.subject | SGRT | pt_PT |
dc.subject | Erros intrafração | pt_PT |
dc.subject | Erros interfração | pt_PT |
dc.subject | Segurança do doente | pt_PT |
dc.subject | Radiotherapy | pt_PT |
dc.subject | Intrafraction errors | pt_PT |
dc.subject | Interfraction errors | pt_PT |
dc.subject | Patient safety | pt_PT |
dc.title | Efeito da utilização da técnica de SGRT (Surface Guided Radiation Therapy) na redução dos erros inter e intra fração em tratamentos SBRT (Stereotatic Body Radiation Therapy) do pulmão | pt_PT |
dc.type | master thesis | |
dspace.entity.type | Publication | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | masterThesis | pt_PT |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Efeito da utilização da técnica de SGRT na redução dos erros inter e intra fração em tratamentos SBRT do pulmão.pdf
- Size:
- 2.16 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: