Browsing by Issue Date, starting with "2015-01"
Now showing 1 - 10 of 45
Results Per Page
Sort Options
- Organizational communication and performance appraisal: 360º feedback and organizational communicationPublication . Mourão, Rita Monteiro; Miranda, SandraOrganizational communication and performance appraisal are essential to human resources management. Organizational communication has been relevant in organizations, especially because globalization and competitiveness create more permanent contact between employees (Miller, 2011). In turn, performance appraisal has been shown to be essential to organizational effectiveness (Proctor and Doukakis, 2003). However, traditional performance evaluation has some limitations (e.g. quotation mistakes associated with the subjectivity of evaluators) (Caetano, 2008). To prevent these limitations, it is important to be aware of 360º evaluation, a specific evaluation method that considers more than one appraiser (Brutus and Gorriti, 2005), and permits to control any eventual idiosyncrasies (Oh and Mount, 2011). This evaluation method is more frequent in organizations with a hierarchical structure of bottom-up (i.e., greater sharing of power) (Brutus and Brassard, 2005). It is expected that the 360º evaluation may be useful to create a better organizational communication, because communication failures tend to occur in organizations with a strong hierarchical structure, due to lower sharing of power among different organizational actors (Felts, 1992). In this case, we describe a theoretical review of these topics, because they have been rarely reported in literature and may be related to each other. In this way, we will present the results of interviews with two experts in the field of organizational communication. These results are important to define organizational communication and 360º evaluation and to create an analysis model about these topics.
- Diagnóstico de avarias em máquinas rotativas utilizando a análise de órbitasPublication . Felício, Gonçalo Miguel Godinho; Roque, António AfonsoEsta dissertação tem como objetivo principal o estudo e análise de órbitas, técnica de diagnóstico de máquinas avançada que é utilizada, nomeadamente, em máquinas de chumaceiras lisas tais como turbinas. A análise de órbitas é uma das componentes de análise de vibrações existente quando, em situação industrial, se opta por seguir a filosofia de manutenção por controlo de condição. Trata-se de uma técnica que monitoriza a vibração relativa entre o rotor e as partes estáticas das máquinas utilizando, para isso, sensores de proximidade. Assim, é possível conhecer o perfil que o movimento do veio traça durante a sua revolução. No presente trabalho é passada em revisão a evolução do conceito de manutenção, suas variantes e estudam-se os princípios da órbita assim como os princípios da instrumentação que permitem medi-la. Utilizando uma unidade demo, foram realizados ensaios em laboratório que permitiram, entre outros, estudar fenómenos como o desequilíbrio, o desalinhamento ou folgas e o modo como se manifestam estes defeitos no funcionamento das máquinas segundo a análise de órbitas. A adicionar a estes ensaios, procedeu-se ao estudode um caso real, inserido na indústria petroquímica, que permitiu o contato com situações reais e elaborar um diagnóstico acerca de três grupos turbocompressores que se revelam fundamentais na produção desta indústria. De acordo com os resultados obtidos, este trabalhoincentiva a prosseguir com novos ensaios de modo a confirmar os valores obtidos assim como explorar novos tipos de defeito.
- O controlo interno nos serviços e fundos autónomosPublication . Miranda, Susana Cristina Ferreira; Santos, Paula Gomes dosA reforma da administração financeira do Estado, durante a década de 90, representou uma transformação estrutural no exercício da gestão financeira pública. Esta transformação levou à mudança substancial do tecido legislativo e à introdução de mecanismos de controlo. Num contexto de verdadeira e profunda reforma financeira, o ordenamento jurídico português é pela primeira vez dotado de um sistema nacional de controlo interno. A presente dissertação, sob a temática de “O controlo interno nos Serviços e Fundos Autónomos”, tem como objetivo determinar, segundo a avaliação do sistema de controlo interno instituído nos diversos organismos, quais os pontos fortes e fracos nas diversas áreas financeiras e patrimoniais assim como percecionar quais os fatores limitativos à ação do controlo interno. Posteriormente à revisão da literatura foi efetuado um estudo empírico, utilizando uma metodologia quantitativa onde foi possível concluir sobre quais as principais medidas e procedimentos de controlo interno que norteiam a atividade financeira dos Serviços e Fundos Autónomos, assim como as limitações sentidas pelos responsáveis dos organismos. No que respeita à questão de investigação que norteou o presente trabalho “ Os Serviços e Fundos Autónomos possuem sistemas de controlo interno que garantam a sua boa governação? ”, pode concluir-se que existe uma tendência para a criação de medidas e ações de controlo pontuais. No entanto, verifica-se que na sua maioria os Serviços e Fundos Autónomos não possuem uma norma de controlo interno nem estão sensibilizados para a sua importância. Como consequência existirão áreas propensas à prática de fraudes, erros ou omissões que conduzirão a uma distorção das Demonstrações Financeiras.
- Projecto e concepção de instalação frigorífica a NH3, para uma unidade de congelação de frangos em contínuo, na VenezuelaPublication . Santos, Pedro Miguel Ferreira de Almeida dos; Santos, Francisco Gonçalves dos; Serrano, Carlos Manuel MartinsNeste relatório de estágio é realizada a concepção de uma instalação frigorífica a Amoníaco na Venezuela, proposta pela empresa H. Seabra. Para realizar este trabalho o autor teve como objectivo inicial o estudo de diversas fontes, por forma a suportar os cálculos através de métodos comprovados teoricamente e experimentalmente, evitando assim a utilização generalizada de regras consideradas como “boa prática”. Primeiro, foi realizado um estudo sobre o balanço térmico frigorífico da instalação, através de duas abordagens: 24 horas e hora-hora. Neste primeiro estudo quantificou-se a diferença entre a carga térmica presente num determinado espaço ao longo do dia, considerando a distribuição das cargas térmicas, com a carga térmica efectivamente presente em determinada hora do dia. Com as cargas térmicas determinadas, procedeu-se ao dimensionamento da instalação frigorífica, através da concepção de um diagrama simplificado que irá permitir a selecção dos diferentes componentes e posterior verificação da adequação da capacidade frigorífica à carga térmica presente na instalação calculada no balanços térmico frigorífico. De seguida, realizou-se uma análise do consumo energético e da eficiência energética da instalação através da análise do COP, regulação da pressão de condensação e instalação de variadores de velocidade. Verificou-se que a utilização da regulação da pressão de condensação permite um ganho substancial na eficiência da instalação, reduzindo o consumo eléctrico anual em cerca de 8,4%. A instalação de variadores de velocidade nos compressores de parafuso não é justificada para esta instalação, sendo que é expectável que estes trabalhem à velocidade de rotação máxima, o que iria introduzir uma redução na eficiência dos mesmos de cerca de 3,5%. A sua utilização pode apenas ser considerada nos compressores alternativos para possibilitar a adequação da capacidade frigorífica à necessária, reduzindo assim o número de arranques dos mesmos e melhorando o tempo de vida útil, apesar de reduzirem a eficiência dos compressores e consequentemente da instalação. Por fim, foi considerada a recuperação de calor para aquecimento de água sanitária, onde foi demonstrada a possibilidade de recuperar 193 kW de calor da instalação frigorífica, valor consideravelmente baixo quando comparado com o calor libertado aquando da condensação, 4422,7 kW.
- Algorithm-oriented design of efficient many-core architectures applied to dense matrix multiplicationPublication . José, Wilson M.; Silva, Ana Rita; Véstias, Mário; Neto, HorácioRecent integrated circuit technologies have opened the possibility to design parallel architectures with hundreds of cores on a single chip. The design space of these parallel architectures is huge with many architectural options. Exploring the design space gets even more difficult if, beyond performance and area, we also consider extra metrics like performance and area efficiency, where the designer tries to design the architecture with the best performance per chip area and the best sustainable performance. In this paper we present an algorithm-oriented approach to design a many-core architecture. Instead of doing the design space exploration of the many core architecture based on the experimental execution results of a particular benchmark of algorithms, our approach is to make a formal analysis of the algorithms considering the main architectural aspects and to determine how each particular architectural aspect is related to the performance of the architecture when running an algorithm or set of algorithms. The architectural aspects considered include the number of cores, the local memory available in each core, the communication bandwidth between the many-core architecture and the external memory and the memory hierarchy. To exemplify the approach we did a theoretical analysis of a dense matrix multiplication algorithm and determined an equation that relates the number of execution cycles with the architectural parameters. Based on this equation a many-core architecture has been designed. The results obtained indicate that a 100 mm(2) integrated circuit design of the proposed architecture, using a 65 nm technology, is able to achieve 464 GFLOPs (double precision floating-point) for a memory bandwidth of 16 GB/s. This corresponds to a performance efficiency of 71 %. Considering a 45 nm technology, a 100 mm(2) chip attains 833 GFLOPs which corresponds to 84 % of peak performance These figures are better than those obtained by previous many-core architectures, except for the area efficiency which is limited by the lower memory bandwidth considered. The results achieved are also better than those of previous state-of-the-art many-cores architectures designed specifically to achieve high performance for matrix multiplication.
- Análise por ultra-sons no controlo de condiçãoPublication . Silveira, Armando; Roque, António Afonso; Silva, Tiago Alexandre Narciso daNo âmbito da manutenção condicionada de equipamentos, o presente trabalho procura aprofundar a técnica da análise de ultra-sons no controlo de condição, como sendo um ensaio não destrutivo, repleto de vantagens e tão pouco usado em Portugal, ao invés da análise de vibrações (amplamente mais utilizado e divulgado). Pretende-se também comparar os ultra-sons com a análise de vibrações A aplicação das técnicas de ultra-sons possui uma enorme relevância como parte integrante de um programa de manutenção condicionada de qualquer instalação industrial, revelando-se por isso interessante estudar o seu potencial na análise da condição dos equipamentos. Procura-se ainda com este trabalho seleccionar e pôr em evidência informação importante relacionada com esta área, e também demonstrar a possibilidade de usar esta técnica como uma forma mais rápida, fácil e intuitiva de verificar o estado da condição de um determinado rolamento. A avaliação da condição do equipamento bem como o estudo da tendência da sua degradação, é conseguida aplicando os ultra-sons, através dos quais se detectam variações no valor médio do nível sonoro ou nos espectros de frequência e sinal no tempo, resultante do seu funcionamento. Em função dessa análise são estabelecidas regras para as intervenções de manutenção, tendo sempre em atenção o objectivo de maximizar a detecção das potenciais avarias (evitando paragens não programadas) e a minimização de intervenções desnecessárias. Através da exploração e implementação da técnica de ultra-sons na manutenção condicionada, tenciona-se aumentar a eficiência dos equipamentos, diminuindo assim o número e tempo de paragem, diminuir os custos de manutenção e colocar a manutenção no centro do processo produtivo.
- HFCs e soluções alternativas viáveisPublication . Rodrigues, Filipe Jorge Rocha; Santos, Francisco Manuel Gonçalves dosOs HFCs (hidrofluorcarbonetos) são fluidos sintéticos, cuja aplicação surgiu naconsequência do Protocolo de Montreal, fazendo parte da política de eliminação progressiva de substâncias destruidoras da camada de ozono. Contudo, posteriormente, o Intergorvernamental Panel on Climate Change [1] concluiu que a Indústria é o principal responsável pelo efeito de estufa do planeta, no qual os fluidos sintéticos possuem um papel determinante. O fenómeno do efeito de estufa leva ao aumento da temperatura média anual terrestre e, consequentemente, aumento do nível dos oceanos, provocando graves desequilíbrios climáticos. A elaboração do Protocolo de Quioto pretende o abrandamento das emissões de gases com efeito de estufa, de forma a reduzir a propagação do aquecimento global. Nas últimas décadas, esses acordos internacionais pressionaram as indústrias de refrigeração e ar condicionado a restringir o uso de fluidos sintéticos com impacte negativo no ambiente. Soluções a longo prazo têm sido estudadas, inclusive, as relacionadas com fluidos naturais. Neste contexto, surge o sistema a R717, usado em algumas instalações industriais, embora apresente um elevado índice de toxicidade que pode pôr em causa a sustentabilidade da instalação, caso o fluido contacte com o produto congelado durante uma fuga. Deste modo, o R717, ainda que de origem natural, requer precauções ao nível da segurança de equipamentos, da construção e da formação dos trabalhadores. Comparativamente, o sistema a HFC, nomeadamente o R404A, não acarreta grandes cuidados de manutenção e, sendo um sistema menos complexo, apresenta um menor investimento inicial. A utilização de um sistema em cascata R744/R717 possibilita a eliminação do problema da contaminação do produto, tirando igualmente partido das vantagens ambientais. Além do aspecto ambiental, os sistemas foram analisados em termos de eficiência energética e económica. Desta comparação, verificou-se que o sistema em cascata, embora com elevado custo inicial, foi o que apresentou melhores resultados em todos os aspectos estudados.
- Contribuição para a definição de procedimentos de inspeção de edifícios correntes após um sismoPublication . Cruz, Susana Retorta da; Baptista, Maria Ana Carvalho Viana; Sousa, Maria LuísaApresentam-se os resultados de uma pesquisa bibliográfica realizada na literatura internacional e nacional referente a fichas de avaliação de danos e operacionalidade de edifícios correntes afetados por sismos. Sistematiza-se o trabalho já realizado em diversas partes do mundo sobre este tema, nomeadamente nos Estados Unidos da América (EUA), na Grécia, na Colômbia, em Itália, na Nova Zelândia, em Espanha e também em Portugal e procede-se à análise crítica das fichas recolhidas. Confere-se especial importância às fichas que já deram provas de aplicação prática, especialmente em regiões do globo com características construtivas semelhantes às portuguesas. Nesta dissertação propõe-se uma ficha de inspeção adequada aos edifícios correntes em Portugal e um manual de procedimentos que acompanha a ficha.
- Aplicação de redes neuronais artificiais à deteção e isolamento de falhas em processos industriaisPublication . Cortez, Vanusa Tavares; Calado, João Manuel FerreiraOs processos industriais são cada vez mais tecnologicamente complexos. Os requisitos de competitividade impostos pelo mercado obrigam as condições de eficiência e operacionalidade próximas dos limites máximos da sua capacidade produtiva. Por outro lado, as paragens intempestivas dos mesmos resultam normalmente em perdas de produção, degradação da qualidade do produto final, danificação dos equipamentos, podendo dar origem a catástrofes ambientais com eventuais perdas de vidas humanas. Estas são principais razões que motivaram a realização deste trabalho e conduziu a esta dissertação. Tem como objetivo, o estudo aplicabilidade de Redes Neuronais Artificiais (RNAS), na deteção e isolamento de falhas que ocorrem em atuadores, utilizados no controlo automático de processos industriais, em tempo real. Permitem que o processo continue a operar de forma controlada, mesmo depois de alguma falha se ter manifestado em algum dos seus atuadores, ou eventualmente, efetuar uma paragem controlada do processo se tal situação ocorrer e não houver capacidade de tolerância á falha em análise. Neste estudo, foi utilizado um reator continuamente agitado (RCA), com nível e temperatura controlados no seu interior, através de duas malhas de controlo e reciclagem parcial do produto final é através de um permutador de calor. Foram simuladas falhas abruptas e incipientes em duas válvulas de regulação, sendo utilizada uma RNA do tipo feedforward, para deteção e isolamento, em tempo real, das falhas simuladas no processo acima mencionado. A RNA foi treinada offline apenas com sintomas de falhas abrutas. O RCA foi simulado com o seu modelo dinâmico utilizando a plataforma computacional MatLab/Simulink, sendo a RNA implementada e treinada com a toolbox de Redes Neuronais do MatLab. O sucesso dos resultados obtidos com os trabalhos de simulação permite perspetivar a utilização de RNAS em situações reais, envolvendo processos industriais de elevada complexidade tecnológica sobretudo, quando é desejável uma atempada deteção e isolamento de falhas, antes de ocorrerem paragens não programadas do processo sobre supervisão.
- Layerwise mixed models for analysis of multilayered piezoelectric composite plates using least-squares formulationPublication . Moleiro, F; Soares, C.M. Mota; Soares, C.A. Mota; Reddy, J.N.This work provides an assessment of layerwise mixed models using least-squares formulation for the coupled electromechanical static analysis of multilayered plates. In agreement with three-dimensional (3D) exact solutions, due to compatibility and equilibrium conditions at the layers interfaces, certain mechanical and electrical variables must fulfill interlaminar C-0 continuity, namely: displacements, in-plane strains, transverse stresses, electric potential, in-plane electric field components and transverse electric displacement (if no potential is imposed between layers). Hence, two layerwise mixed least-squares models are here investigated, with two different sets of chosen independent variables: Model A, developed earlier, fulfills a priori the interiaminar C-0 continuity of all those aforementioned variables, taken as independent variables; Model B, here newly developed, rather reduces the number of independent variables, but also fulfills a priori the interlaminar C-0 continuity of displacements, transverse stresses, electric potential and transverse electric displacement, taken as independent variables. The predictive capabilities of both models are assessed by comparison with 3D exact solutions, considering multilayered piezoelectric composite plates of different aspect ratios, under an applied transverse load or surface potential. It is shown that both models are able to predict an accurate quasi-3D description of the static electromechanical analysis of multilayered plates for all aspect ratios.