Percorrer por autor "Pinto, Sónia Ferreira"
A mostrar 1 - 3 de 3
Resultados por página
Opções de ordenação
- High frequency transformers for solid-state transformer applicationsPublication . Santos, Nuno; Chaves, Miguel; Gamboa, Paulo; Cordeiro, Armando; Santos, Nelson; Pinto, Sónia FerreiraThis paper focuses on the study of the high frequency transformer incorporated in solid- state transformers, specifically on the development of the steps that enable the design of an optimized high frequency transformer and its equivalent model based on the desired characteristics. The impact of operating a transformer at high frequency and the respective solutions that allow this impact to be reduced are analyzed, alongside the numerous advantages that the utilization of these transformers has over traditional 50/60 Hz transformers. Furthermore, the power scheme of the solid-state transformer is outlined, focusing on the power converters, which are immediately before and after the high frequency transformer (HFT). We also investigate a control technique that allows for correct operation and the existence of power bidirectionality. In a novel approach, this paper demonstrates the systematic steps for designing an HFT according to the desired specifications of each given project, helping students and engineers achieve their objectives in power-electronic applications. Moreover, this paper aims at increasing the knowledge of this area of power electronics and facilitating the development of new topologies with high power density, which are very important to the integration of renewable power sources and other applications. Finally, a simulation is presented to validate a high frequency transformer and its control technique.
- Inverse dynamics based predictive control for unified power flow controllers without DC busPublication . Monteiro, Joaquim; Silva, Fernando José; Pinto, Sónia Ferreira; Palma, João Carlos Pires daThis paper presents a new predictive digital control method applied to Matrix Converters (MC) operating as Unified Power Flow Controllers (UPFC). This control method, based on the inverse dynamics model equations of the MC operating as UPFC, just needs to compute the optimal control vector once in each control cycle, in contrast to direct dynamics predictive methods that needs 27 vector calculations. The theoretical principles of the inverse dynamics power flow predictive control of the MC based UPFC with input filter are established. The proposed inverse dynamics predictive power control method is tested using Matlab/Simulink Power Systems toolbox and the obtained results show that the designed power controllers guarantees decoupled active and reactive power control, zero error tracking, fast response times and an overall good dynamic and steady-state response.
- Linear and sliding-mode control design for matrix converter-based unified power flow controllersPublication . Monteiro, Joaquim; Silva, José Fernandes Alves da; Pinto, Sónia Ferreira; Palma, João Carlos Pires daThis paper presents the design and compares the performance of linear, decoupled and direct power controllers (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFC). A simplified steady-state model of the matrix converter-based UPFC fitted with a modified Venturini high-frequency pulse width modulator is first used to design the linear controllers for the transmission line active (P) and reactive (Q) powers. In order to minimize the resulting cross coupling between P and Q power controllers, decoupled linear controllers (DLC) are synthesized using inverse dynamics linearization. DPC are then developed using sliding-mode control techniques, in order to guarantee both robustness and decoupled control. The designed P and Q power controllers are compared using simulations and experimental results. Linear controllers show acceptable steady-state behaviour but still exhibit coupling between P and Q powers in transient operation. DLC are free from cross coupling but are parameter sensitive. Results obtained by DPC show decoupled power control with zero error tracking and faster responses with no overshoot and no steady-state error. All the designed controllers were implemented using the same digital signal processing hardware.
