Logo do repositório
 
Miniatura indisponível
Publicação

Optimal scheduling of a pumped storage hydro unit in the day-ahead and secondary reserve electricity market

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
JLagarto.pdf363.46 KBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

Ancillary services play a major role in power systems security and stability. The transmission systems operators contract some of these services at minimum cost in competitive markets. This is the case of the secondary reserve market (SRM). Besides the day-ahead market (DAM) generating companies, aiming at maximize their profits, can increase their revenues by selling available capacity in the SRM. This paper presents the solution of a price-taker generating company, owning a pumped-storage hydro (PSH) unit, acting in DAM and SRM. The results were obtained for three case studies: the generating company acts only in the DAM; the generating company acts in both markets with a fixed pumping capacity of the PSH unit; the generating company acts in both markets with a variable pumping capacity of the PSH unit. Results show that higher profits are obtained when acting in both markets with a variable pumping capacity of the PSH unit.

Descrição

Palavras-chave

Ancillary services Day-ahead market Pumped-hydro storage Secondary reserve market

Contexto Educativo

Citação

LAGARTO, João; [et al] – Optimal scheduling of a pumped storage hydro unit in the day-ahead and secondary reserve electricity market. In 2015 12th International Conference on the European Energy Market (EEM). Lisbon, Portugal: IEEE, 2015. ISBN 978-1-4673-6692-2. Pp. 1-5

Projetos de investigação

Projeto de investigaçãoVer mais

Unidades organizacionais

Fascículo

Editora

IEEE

Licença CC

Métricas Alternativas