Publication
Are we neglecting the importance of azole resistance screening in indoor air quality assessments?
dc.contributor.author | Viegas, Carla | |
dc.contributor.author | Almeida, Beatriz | |
dc.contributor.author | Gomes, Bianca | |
dc.contributor.author | Dias, Marta | |
dc.contributor.author | Cervantes, Renata | |
dc.contributor.author | Caetano, Liliana Aranha | |
dc.date.accessioned | 2022-03-07T15:29:20Z | |
dc.date.available | 2022-03-07T15:29:20Z | |
dc.date.issued | 2022-02 | |
dc.description | Project “Waste Workers’ Exposure to Bioburden in the Truck Cab during Waste Management - W2E Bioburden” (IPL/2016/W2E_ESTeSL). | pt_PT |
dc.description | Project “Occupational exposure of ambulance drivers to bioburden” (IPL/2020/BIO-AmbuDrivers_ESTeSL). | pt_PT |
dc.description | FCT_UIDB/05608/2020. FCT_UIDP/05608/2020. | pt_PT |
dc.description | Best poster award | pt_PT |
dc.description.abstract | Introduction: The microbial exposure, as well as their metabolic products, has been frequently reported as a high risk of respiratory effects and general health hazards. Regarding the Portuguese legislation for IAQ, the microbial assessment covers only air sampling and culture-based methods (malt extract agar as only culture media to be applied). Fungal legal criteria consist of a fungal load ratio between indoor and outdoor, which should be lower than 1 (I/O<1). Purpose: Analyze the importance of including the characterization of the azole resistance profile in indoor air quality assessments. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Viegas C, Almeida B, Gomes B, Dias M, Cervantes R, Caetano LA. Are we neglecting the importance of azole resistance screening in indoor air quality assessments? In: 10th Advances Against Aspergillosis and Mucormycosis [online], February 2-3, 2020. poster 58. | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.21/14390 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.relation | Project “Waste Workers’ Exposure to Bioburden in the Truck Cab during Waste Management - W2E Bioburden” (IPL/2016/W2E_ESTeSL) | pt_PT |
dc.relation | Project “Occupational exposure of ambulance drivers to bioburden” (IPL/2020/BIO-AmbuDrivers_ESTeSL) | pt_PT |
dc.relation | FCT_UIDB/05608/2020 | pt_PT |
dc.relation | FCT_UIDP/05608/2020 | pt_PT |
dc.relation.publisherversion | https://collaborativeconferences-registration.co.uk/aaam2022/files/58.pdf | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_PT |
dc.subject | Environmental health | pt_PT |
dc.subject | Fungal contamination | pt_PT |
dc.subject | Azole resistance | pt_PT |
dc.subject | Indoor air | pt_PT |
dc.subject | Air quality | pt_PT |
dc.subject | Project “Waste Workers’ Exposure to Bioburden in the Truck Cab during Waste Management - W2E Bioburden” | pt_PT |
dc.subject | IPL/2016/W2E_ESTeSL | pt_PT |
dc.subject | Project “Occupational exposure of ambulance drivers to bioburden” | pt_PT |
dc.subject | IPL/2020/BIO-AmbuDrivers_ESTeSL | pt_PT |
dc.subject | FCT_UIDB/05608/2020 | pt_PT |
dc.subject | FCT_UIDP/05608/2020 | pt_PT |
dc.title | Are we neglecting the importance of azole resistance screening in indoor air quality assessments? | pt_PT |
dc.type | conference object | |
dspace.entity.type | Publication | |
person.familyName | Viegas | |
person.familyName | Gomes | |
person.familyName | Dias | |
person.familyName | Wellenkamp de Carvalho Freire de Cervantes | |
person.familyName | Aranha Caetano | |
person.givenName | Carla | |
person.givenName | Bianca | |
person.givenName | Marta | |
person.givenName | Renata | |
person.givenName | Liliana | |
person.identifier | 2371423 | |
person.identifier.ciencia-id | EE1E-C639-D70F | |
person.identifier.ciencia-id | AD1E-B4CE-389D | |
person.identifier.ciencia-id | 4E1B-16BB-80C7 | |
person.identifier.ciencia-id | 6018-3CC9-B640 | |
person.identifier.ciencia-id | 9716-9DAC-532A | |
person.identifier.orcid | 0000-0002-1545-6479 | |
person.identifier.orcid | 0000-0002-6264-6072 | |
person.identifier.orcid | 0000-0002-2704-6995 | |
person.identifier.orcid | 0000-0001-5990-4168 | |
person.identifier.orcid | 0000-0003-1496-2609 | |
person.identifier.rid | B-7217-2013 | |
person.identifier.scopus-author-id | 55443609700 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | conferenceObject | pt_PT |
relation.isAuthorOfPublication | b5fa5da4-50c3-4b88-ae20-1bc63cb485f7 | |
relation.isAuthorOfPublication | 4f639ef6-2716-49c5-a7e0-75bf0acf6ebc | |
relation.isAuthorOfPublication | 564f2806-6e1e-418d-8d93-737922ad6601 | |
relation.isAuthorOfPublication | 28678633-1f6a-4b79-8150-12a857f4a531 | |
relation.isAuthorOfPublication | 6517c656-f913-4f54-8682-77c2856c9e4c | |
relation.isAuthorOfPublication.latestForDiscovery | b5fa5da4-50c3-4b88-ae20-1bc63cb485f7 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Are we neglecting the importance of azole resistance screening in indoor air quality assessments.pdf
- Size:
- 551.7 KB
- Format:
- Adobe Portable Document Format