Avaliação da conformidade metrológica de instrumentos médicos

dc.contributor.advisorMatos, Manuel
dc.contributor.advisorFerreira, Maria do Céu Lopes de Sousa
dc.contributor.authorMagueijo, Filipa Maria Pires
dc.date.accessioned2019-06-07T14:09:46Z
dc.date.available2019-06-07T14:09:46Z
dc.date.issued2018-12-17
dc.descriptionTrabalho final de mestrado para obtenção do grau de mestre em Engenharia Biomédicapt_PT
dc.description.abstractNos dias de hoje, é de fácil acesso à população a compra e uso de alguns instrumentos médicos, ora com o objectivo de monitorizar um doente, ora com o objectivo de uma medição esporádica. No âmbito da saúde, a tomada de decisão clínica é sustentada pelo auxilio dos mais diversos aparelhos médicos, de maneira a que haja uma evidência e ciência por onde basear. Contudo, esta decisão pode, também, ser tomada por um simples paciente, que se automedique em função de valores adquiridos nos instrumentos de fácil acesso. Por estes motivos referidos acima, foram estudadas as componentes metrológicas de equipamentos médicos, nomeadamente a calibração, os diferentes tipos de manutenção, os conceitos de medição, erro e incerteza. De seguida, foi também analisado o funcionamento dos diversos instrumentos, do conceito anatómico ao conceito electrónico/mecânico e, por último, o impacto na saúde pública, ou seja, o que uma leitura errada pode provocar no paciente – desde uma ida urgente ao médico com falsos diagnósticos à automedicação. Posteriormente, foi elaborado um estudo, tendo em conta uma pequena amostra da população, adquirindo dez medições seguidas, de instrumentos vulgares disponíveis nas suas casas para que se pudesse comparar o seu comportamento (variabilidade) com instrumentos de referência. Os instrumentos usados neste estudo foram termómetros digitais, termómetros de infra vermelhos, medidores de pressão arterial, oxímetros e balanças.pt_PT
dc.description.abstractNowadays, general population can easily access, purchase and use medical equipment, either to constantly monitorize a patient, either to perform a quick spontaneous measurement. In the health field, the clinical decision making process is supported by the help of several medical instruments, so there is an evidence and scientific reason. However, this decision can also be made by a normal person, without medical expertise, that self-medicates himself, based on the results acquired on the same easy access medical instrument used. For the reasons mentioned above, the medical equipment metrological components were studied, more specifically calibration, the several types of maintenance, the concepts of measurements, error and uncertainty. Therefore, it was also analyzed the operating mode of several medical apparatuses, not only from the anatomical point of view but also from the electric/mechanical point of view and, ultimately the impact on public health, meaning the consequences or causes of bad reading – the patient might want to go urgently to the hospital with a false diagnostic or might end up self-medicating. Finally, a study was done, considering a small amount of general population by acquiring ten measurements in a row, using medical instruments from their houses, so a comparison of their variability could be made with master/reference instruments. The medical apparatus used in this study were digital thermometers, infrared thermometers, blood pressure monitors, oximeters and body scales.pt_PT
dc.description.versionN/Apt_PT
dc.identifier.citationMAGUEIJO, Filipa Maria Pires - Avaliação da conformidade metrológica de instrumentos médicos. Lisboa: Instituto Superior de Engenharia de Lisboa - Escola Superior de Tecnologia da Saúde de Lisboa, 2018. Dissertação de mestrado.pt_PT
dc.identifier.tid202253406
dc.identifier.urihttp://hdl.handle.net/10400.21/10133
dc.language.isoporpt_PT
dc.peerreviewedyespt_PT
dc.publisherInstituto Superior de Engenharia de Lisboa - Escola Superior de Tecnologia da Saúde de Lisboapt_PT
dc.subjectInstrumentos médicospt_PT
dc.subjectMedical instrumentspt_PT
dc.subjectMetrologiapt_PT
dc.subjectMetrologypt_PT
dc.subjectVariabilidadept_PT
dc.subjectVariabilitypt_PT
dc.subjectSaúde públicapt_PT
dc.subjectPublic healthpt_PT
dc.titleAvaliação da conformidade metrológica de instrumentos médicospt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Dissertação.pdf
Size:
1.51 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Anexos.pdf
Size:
3.49 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: