Projecto de reforço de um edifício de habitação com planta em forma de "L", do tipo "placa" de médio porte

dc.contributor.advisorLamego, Paula Raquel Pires da Cunha
dc.contributor.authorAlmeida, Joana Sofia Matias Resina de
dc.date.accessioned2018-09-10T16:11:48Z
dc.date.available2018-09-10T16:11:48Z
dc.date.issued2017-01-26
dc.descriptionTrabalho final de mestrado para obtenção do grau de Mestre em Engenharia Civilpt_PT
dc.description.abstractNas últimas décadas, tem sido reforçado o estudo do comportamento estrutural de edifícios novos e de edifícios existentes quando sujeitos à acção sísmica, sendo este facto demonstrado com a evolução regulamentar ao nível da Engenharia Civil. Pela sua localização geográfica, Portugal é caracterizado pelo risco de ocorrência de sismos de intensidade considerável. Considerando que uma parte do edificado nacional foi projectado segundo regulamentos que não previam as acções sísmicas, torna-se indispensável em termos de prevenção a verificação de que as estruturas existentes garantem a segurança para as novas exigências regulamentares e normativas. Neste trabalho é desenvolvido um projecto de reforço estrutural de um edifício existente, do tipo "placa", anterior à aplicação de exigências sísmicas. O estudo é iniciado com a avaliação da segurança do edifício, que inclui a análise da vulnerabilidade sísmica do mesmo, comparando a sua capacidade resistente com o seu comportamento face à acção sísmica. Este estudo resulta de uma análise estática não linear ou pushover realizada pelo programa 3Muri (S.T.A. DATA, 2015b). Verificada a necessidade de intervenção ao nível estrutural do edifício, são estudadas soluções correntes de reforço, com o objectivo de reduzir a vulnerabilidade sísmica e, consequentemente, melhorar o desempenho sísmico do edifício. Para as várias soluções de reforço, é verificada a sua viabilidade técnica, resultante das respectivas análises sísmicas efectuadas. São determinados os custos envolvidos para a execução dos reforços, bem como a redução das previsões de perdas materiais e humanas face à ocorrência de um sismo, comparativamente aos valores obtidos para o edifício não reforçado. A solução de reforço verificada como a mais viável ao nível técnico e económico, é alvo de pormenorização ao nível das peças desenhadas, constituindo assim o projecto de reforço estrutural do edifício. De uma forma geral, pretende-se com este projecto avaliar o benefício da introdução de reforços estruturais, através da aplicação de um processo de análise da segurança estrutural e da viabilidade técnica e económica, bem como elaborar o projecto de execução de reforço de um edifício de habitação construído antes de 1983.pt_PT
dc.description.abstractThe study of new and existing buildings structural behaviour when exposed to seismic actions, has been improved during the last decades, according to the developments in civil engineering regulations. Due to its location, Portugal is considered to have a significant earthquake risk. Some of the buildings in Portugal were built without any regulation that contemplate the seismic actions, so it became crucial in terms of a prevention that the existing buildings need to ensure safety according to the new regulation and normative requirements. In this thesis, it was developed a structural reinforcement project for an existing building, which was designed before seismic requirements were regulated. This study begins with the building safety evaluation that includes the seismic vulnerability analysis by comparing the bearing capacity with the seismic behaviour. The study comes as a result of a nonlinear static analysis, also known as pushover, performed by 3Muri software (S.T.A. DATA, 2015b). After verifying the need for structural intervention, the common reinforcement solutions were studied in order to reduce vulnerability and improve the seismic performance. For those solutions it was verified the technical viability in accordance with the seismic analysis performed. The execution costs of the reinforcement solutions were also studied as well as the decrease of material and human losses associated with the occurrence of an earthquake. So it is possible to compare this indicators with the ones from the existing building without any applied reinforcement. The solution with the best technical and economic viability is validated and detailed in technical drawings. In general, this projects purpose is to assess some possible solutions of structural reinforcement (through a process that considers structural safety analysis and technical and economic viability) and to elaborate the project of reinforcement of a residential building built before 1983.pt_PT
dc.description.versionN/Apt_PT
dc.identifier.citationALMEIDA, Joana Sofia Matias Resina de - Projecto de reforço de um edifício de habitação com planta em forma de "L", do tipo "placa" de médio porte. Lisboa: Instituto Superior de Engenharia de Lisboa, 2017. Dissertação de mestrado.pt_PT
dc.identifier.tid201973391
dc.identifier.urihttp://hdl.handle.net/10400.21/8849
dc.language.isoporpt_PT
dc.peerreviewedyespt_PT
dc.publisherInstituto Superior de Engenharia de Lisboapt_PT
dc.subjectDesempenho sísmicopt_PT
dc.subjectSeismic behaviourpt_PT
dc.subjectDano sísmicopt_PT
dc.subjectSeismic damagept_PT
dc.subjectProjecto reforçopt_PT
dc.subjectReinforcement projectpt_PT
dc.subjectReforço estruturalpt_PT
dc.subjectStructural reinforcementpt_PT
dc.subjectVulnerabilidade sísmicapt_PT
dc.subjectSeismic vulnerabilitypt_PT
dc.subjectViabilidade económicapt_PT
dc.subjectEconomic viabilitypt_PT
dc.titleProjecto de reforço de um edifício de habitação com planta em forma de "L", do tipo "placa" de médio portept_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Dissertação.pdf
Size:
5.36 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: