Publication
Blade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converter
dc.contributor.author | Seixas, Mafalda | |
dc.contributor.author | Melício, R. | |
dc.contributor.author | Mendes, Victor | |
dc.contributor.author | Couto, C. | |
dc.date.accessioned | 2017-06-23T09:12:21Z | |
dc.date.available | 2017-06-23T09:12:21Z | |
dc.date.issued | 2016 | |
dc.description.abstract | This paper is on a wind energy conversion system simulation of a transient analysis due to a blade pitch control malfunction. The aim of the transient analysis is the study of the behavior of a back-to-back multiple point clamped five-level full-power converter implemented in a wind energy conversion system equipped with a permanent magnet synchronous generator. An alternate current link connects the system to the grid. The drive train is modeled by a three-mass model in order to simulate the dynamic effect of the wind on the tower. The control strategy is based on fractional-order control. Unbalance voltages in the DC-link capacitors are lessen due to the control strategy, balancing the capacitor banks voltages by a selection of the output voltage vectors. Simulation studies are carried out to evaluate not only the system behavior, but also the quality of the energy injected into the electric grid. | pt_PT |
dc.description.sponsorship | LAETA 2015-2020 | |
dc.description.sponsorship | UID/EMS/50022/2013 | |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | SEIXAS, M.; [et al] - Blade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converter. Renewable Energy. ISSN 0960-1481. Vol. 89 (2016), pp. 339-350 | pt_PT |
dc.identifier.doi | 10.1016/j.renene.2015.12.005 | pt_PT |
dc.identifier.issn | 0960-1481 | |
dc.identifier.uri | http://hdl.handle.net/10400.21/7196 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Elsevier | pt_PT |
dc.relation.publisherversion | http://ac.els-cdn.com/S096014811530505X/1-s2.0-S096014811530505X-main.pdf?_tid=82169954-57f2-11e7-8eff-00000aacb35e&acdnat=1498208653_1bfe8dbf88e8113938744b6f3c052722 | pt_PT |
dc.subject | Wind energy | pt_PT |
dc.subject | Five-level power converter | pt_PT |
dc.subject | Drive train | pt_PT |
dc.subject | Fractional-order control | pt_PT |
dc.subject | Simulation | pt_PT |
dc.title | Blade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converter | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 350 | pt_PT |
oaire.citation.startPage | 339 | pt_PT |
oaire.citation.title | Renewable Energy | pt_PT |
oaire.citation.volume | 89 | pt_PT |
person.familyName | Seixas | |
person.familyName | Mendes | |
person.givenName | Mafalda | |
person.givenName | Victor | |
person.identifier.orcid | 0000-0002-8078-9317 | |
person.identifier.orcid | 0000-0002-4599-477X | |
person.identifier.rid | D-2332-2012 | |
person.identifier.scopus-author-id | 56022242600 | |
person.identifier.scopus-author-id | 55138675600 | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | 622605ea-3c85-4994-8ada-9757a052aa12 | |
relation.isAuthorOfPublication | a86b9291-f23c-4f09-83d7-9ee691696705 | |
relation.isAuthorOfPublication.latestForDiscovery | 622605ea-3c85-4994-8ada-9757a052aa12 |