Repository logo
 
Publication

Blade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converter

dc.contributor.authorSeixas, Mafalda
dc.contributor.authorMelício, R.
dc.contributor.authorMendes, Victor
dc.contributor.authorCouto, C.
dc.date.accessioned2017-06-23T09:12:21Z
dc.date.available2017-06-23T09:12:21Z
dc.date.issued2016
dc.description.abstractThis paper is on a wind energy conversion system simulation of a transient analysis due to a blade pitch control malfunction. The aim of the transient analysis is the study of the behavior of a back-to-back multiple point clamped five-level full-power converter implemented in a wind energy conversion system equipped with a permanent magnet synchronous generator. An alternate current link connects the system to the grid. The drive train is modeled by a three-mass model in order to simulate the dynamic effect of the wind on the tower. The control strategy is based on fractional-order control. Unbalance voltages in the DC-link capacitors are lessen due to the control strategy, balancing the capacitor banks voltages by a selection of the output voltage vectors. Simulation studies are carried out to evaluate not only the system behavior, but also the quality of the energy injected into the electric grid.pt_PT
dc.description.sponsorshipLAETA 2015-2020
dc.description.sponsorshipUID/EMS/50022/2013
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationSEIXAS, M.; [et al] - Blade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converter. Renewable Energy. ISSN 0960-1481. Vol. 89 (2016), pp. 339-350pt_PT
dc.identifier.doi10.1016/j.renene.2015.12.005pt_PT
dc.identifier.issn0960-1481
dc.identifier.urihttp://hdl.handle.net/10400.21/7196
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttp://ac.els-cdn.com/S096014811530505X/1-s2.0-S096014811530505X-main.pdf?_tid=82169954-57f2-11e7-8eff-00000aacb35e&acdnat=1498208653_1bfe8dbf88e8113938744b6f3c052722pt_PT
dc.subjectWind energypt_PT
dc.subjectFive-level power converterpt_PT
dc.subjectDrive trainpt_PT
dc.subjectFractional-order controlpt_PT
dc.subjectSimulationpt_PT
dc.titleBlade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converterpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage350pt_PT
oaire.citation.startPage339pt_PT
oaire.citation.titleRenewable Energypt_PT
oaire.citation.volume89pt_PT
person.familyNameSeixas
person.familyNameMendes
person.givenNameMafalda
person.givenNameVictor
person.identifier.orcid0000-0002-8078-9317
person.identifier.orcid0000-0002-4599-477X
person.identifier.ridD-2332-2012
person.identifier.scopus-author-id56022242600
person.identifier.scopus-author-id55138675600
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication622605ea-3c85-4994-8ada-9757a052aa12
relation.isAuthorOfPublicationa86b9291-f23c-4f09-83d7-9ee691696705
relation.isAuthorOfPublication.latestForDiscovery622605ea-3c85-4994-8ada-9757a052aa12

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Blade_VMFMendes_ADEEEA.pdf
Size:
1.74 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: