Força de preensão – Análise de concordância entre dois dinamómetros: JAMAR vs E‑Link

dc.contributor.authorTomás, Maria Teresa
dc.contributor.authorFernandes, Beatriz
dc.date.accessioned2012-08-08T14:56:07Z
dc.date.available2012-08-08T14:56:07Z
dc.date.issued2012-05
dc.description.abstractIntrodução – Avaliar a força de preensão mostrou ser de primordial importância pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e, assim, estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E‑Link (Biometrics) que fornece o valor da força máxima (peak force), para além de outras variáveis, como a taxa de fadiga. Não existem, contudo, estudos que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá‑los indistintamente. Objetivos – Avaliar a concordância entre as medições da força de preensão (força máxima ou peak force em Kg) obtida a partir de dois equipamentos diferentes (dinamómetros portáteis): um computorizado (E‑Link, Biometrics) e outro hidráulico (JAMAR). Metodologia – Foram avaliados 29 indivíduos (13H; 16M; 22±7 anos; 23,2±3,3 kg/m2) em 2 dias consecutivos, na mesma altura do dia. A posição de teste escolhida foi a recomendada pela Associação Americana de Terapeutas Ocupacionais e foi escolhido o melhor resultado de entre 3 tentativas para a mão dominante. Realizou‑se uma análise correlacional entre os valores obtidos na variável analisada em cada equipamento (coeficiente de Spearman) e uma análise de Bland & Altman para verificar a concordância entre as duas medições. Resultados – O coeficiente de correlação entre as duas medições foi elevado (rS= 0,956; p<0,001) e, pela análise de Bland & Altman, os valores obtidos encontram‑se todos dentro do intervalo da média±2SD. Conclusões – As duas medições mostraram ser concordantes, revelando que os dinamómetros testados podem ser comparáveis ou utilizados indistintamente em diferentes estudos e populações. ABSTRACT: Introduction – Assess grip strength has proved to be of vital importance because of its relationship with functional capacity of individuals, in order to determine levels of risk for future disability and thereby establish prevention strategies. Most studies use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement. However, there are other dynamometers available, such as portable computerized dynamometer E‑Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue. There are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. Purpose – To evaluate the agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E‑Link, Biometrics) and a hydraulic (JAMAR). Methodology – 29 subjects (13H, 16M, 22 ± 7 years, 23.2 ± 3.3 kg/m2) were assessed on two consecutive days at the same time of day. The test position chosen was recommended by the American Association of Occupational Therapists and was considered the best result from three attempts for the dominant hand. A correlation was studied between values obtained in the variable analyzed in each equipment (Spearman coefficient) and Bland‑Altman analysis to assess the agreement between the two measurements. Results – The correlation coefficient between the two measurements was high (rs = 0,956, p <0,001) and Bland & Altman analysis of the values obtained are all within the range of mean±2SD. Conclusions – The two measurements were shown to be concordant, revealing that the tested dynamometers can be comparable or used interchangeably in different studies and populations.por
dc.identifier.citationTomás MT, Fernandes B. Força de preensão – Análise de concordância entre dois dinamómetros: JAMAR vs E‑Link. Saúde & Tecnologia. 2012;(7):39-43.por
dc.identifier.issn1646-9704
dc.identifier.urihttp://hdl.handle.net/10400.21/1697
dc.language.isoporpor
dc.peerreviewedyespor
dc.publisherEscola Superior de Tecnologia da Saúde de Lisboapor
dc.relation.publisherversionhttp://www.estesl.ipl.pt/Sites/estesl/Publico/ST_RecEd/GAM/S&T_7_6.pdfpor
dc.subjectFisioterapiapor
dc.subjectPreensãopor
dc.subjectDinamómetropor
dc.subjectAnálise de concordânciapor
dc.subjectBland & Altmanpor
dc.subjectPhysiotherapypor
dc.subjectGrippor
dc.subjectDynamometerpor
dc.subjectAgreement analysispor
dc.titleForça de preensão – Análise de concordância entre dois dinamómetros: JAMAR vs E‑Linkpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage43por
oaire.citation.startPage39por
oaire.citation.titleSaúde & Tecnologiapor
person.familyNameTomás
person.givenNameMaria Teresa
person.identifier438585
person.identifier.ciencia-id3010-19D6-C7A5
person.identifier.orcid0000-0003-0491-8903
person.identifier.ridN-1940-2013
person.identifier.scopus-author-id36700434200
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication64ad74a4-4cd4-426e-a1ee-2ec846fdc6dd
relation.isAuthorOfPublication.latestForDiscovery64ad74a4-4cd4-426e-a1ee-2ec846fdc6dd

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Análise de concordância entre dois dinamometros.pdf
Size:
1.86 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections