Repository logo
 
Publication

Influence of attenuation correction in the MPI image reconstructed by the ‘Evolution for Cardiac’™

dc.contributor.authorRibeiro, Daniela
dc.contributor.authorVilaça, Joana
dc.contributor.authorNunes, Cristiano
dc.contributor.authorFreire, Luís
dc.contributor.authorPinheiro, Marco
dc.contributor.authorCantinho, Guilhermina
dc.contributor.authorCarolino, Elisabete
dc.contributor.authorSousa, Eva
dc.date.accessioned2015-11-04T14:26:00Z
dc.date.available2015-11-04T14:26:00Z
dc.date.issued2015-10
dc.description.abstractThe acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.pt_PT
dc.identifier.citationRibeiro D, Vilaça J, Nunes C, Freire L, Carolino E, Sousa E, et al. Influence of attenuation correction in the MPI image reconstructed by the ‘Evolution for Cardiac’™. In EANM'15 – Annual Congress of the European Association of Nuclear Medicine, Hamburg (Germany), October 10-14, 2015.pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/5346
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.relation.publisherversionhttp://eanm15.eanm.org/programme/docs/FINAL_EANM15_CTE_ABSTRACT_BOOK.pdfpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectNuclear medicinept_PT
dc.subjectMyocardial perfusion imagept_PT
dc.subjectCoronary artery diseasept_PT
dc.subjectComputerized tomographypt_PT
dc.titleInfluence of attenuation correction in the MPI image reconstructed by the ‘Evolution for Cardiac’™pt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceHamburgopt_PT
person.familyNameCarolino
person.givenNameElisabete
person.identifier.ciencia-id1216-EFA3-1E0F
person.identifier.orcid0000-0003-4165-7052
person.identifier.ridF-1012-2015
person.identifier.scopus-author-id25821697000
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication77930d39-ed34-44dc-a4a6-9bf833e5e688
relation.isAuthorOfPublication.latestForDiscovery77930d39-ed34-44dc-a4a6-9bf833e5e688

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Influence of attenuation correction in the MPI image reconstructed by the ‘Evolution for Cardiac’.pdf
Size:
595.22 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections