Repository logo
 
Publication

Impact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patients

datacite.subject.sdg03:Saúde de Qualidade
dc.contributor.authorLeote, João
dc.contributor.authorGonçalves, Andreia
dc.contributor.authorFonseca, Júlia
dc.contributor.authorLoução, Ricardo
dc.contributor.authorDias, Maria Hermínia Monteiro Brites
dc.contributor.authorRibeiro, Maria Inês
dc.contributor.authorMeireles, Ricardo
dc.contributor.authorVarudo, Rita
dc.contributor.authorBacariza, Jacobo
dc.contributor.authorGonzalez, Filipe
dc.date.accessioned2025-01-20T11:52:54Z
dc.date.available2025-01-20T11:52:54Z
dc.date.issued2025-01
dc.description.abstractThe number of vertical artefacts (VAs) in lung ultrasound (LUS) impacts patients' clinical management. This study aimed to demonstrate the influence of ultrasound settings on the number of VAs in patients under invasive mechanical ventilation (IMV). Methods: Patients under IMV were recruited for LUS, including three breathing cycles with a motionless curvilinear probe on the thoracic region with the most VAs. Three experts in LUS were asked about the number of VAs at random, and blinded after altering the settings for a total of 20 test recordings per patient. The correlation between expert classifications was tested after grading the classifications. The number of VAs across clinicians was compared between baseline recordings and test condition recordings to determine statistical differences. Results: 29 patients were enrolled with a median Sequential Organ Failure Assessment score of 6 (interquartile range (IQR) 3). IMV was mainly due to stroke (n=10) and pneumonia (n=6). LUS was made between days 1 and 6 (IQR). Baseline recordings showed a median of 2±2 VAs in inspiration and a median of 1±2 in expiration from 3636 expert classifications, with a strong agreement among patients. A probe frequency of 8 MHz, artefact filtering, speckle reduction, and frame average reduced the median VA number by one. A power of -20 dB and a dynamic range of 32 dB abolished the VAs. A gain above 90% increased the median number of VAs by one. Conclusion: In this in vivo study, the LUS settings influenced the VA number in IMV patients, after controlling for physiological and operator confounders.eng
dc.identifier.citationLeote J, Gonçalves A, Fonseca J, Loução R, Dias H, Ribeiro MI, et al. Impact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patients. ERJ Open Res. 2025;11(1):483.
dc.identifier.doi10.1183/23120541.00483-2024
dc.identifier.pmid39811554
dc.identifier.urihttp://hdl.handle.net/10400.21/21327
dc.language.isoeng
dc.peerreviewedyes
dc.publisherPubMed Central
dc.relation.hasversionhttps://publications.ersnet.org/content/erjor/11/1/00483-2024
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectPneumology
dc.subjectUltrasound
dc.subjectMechanically ventilated
dc.subjectLung ultrasound
dc.titleImpact of ultrasound settings on lung vertical artefacts: an observational study in mechanically ventilated patientspor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue1
oaire.citation.startPage483
oaire.citation.titleERJ Open Research
oaire.citation.volume11
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
person.familyNameDias
person.givenNameMaria Hermínia Monteiro Brites
person.identifier.orcid0000-0003-1257-8734
relation.isAuthorOfPublication4ba812bb-8b70-4413-af7a-91e0f04cbad7
relation.isAuthorOfPublication.latestForDiscovery4ba812bb-8b70-4413-af7a-91e0f04cbad7

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Impact of ultrasound settings on lung vertical artefacts_an observational study in mechanically ventilated patients.pdf
Size:
548.93 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.03 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections