Study of the influence of count’s number in myocardium in the determination of reproducible functional parameters in Gated-SPECT studies simulated with GATE

dc.contributor.authorVieira, Lina
dc.contributor.authorSousa, Eva
dc.contributor.authorVaz, Tânia
dc.contributor.authorCosta, Durval C.
dc.contributor.authorAlmeida, Pedro
dc.date.accessioned2013-05-17T14:31:36Z
dc.date.available2013-05-17T14:31:36Z
dc.date.issued2012-10
dc.description.abstractMyocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. But standard protocols of the Gated-SPECT studies require long acquisition times for each study. It is therefore important to reduce as much as possible the total duration of image acquisition. However, it is known that this reduction leads to decrease on counts statistics per projection and raises doubts about the validity of the functional parameters determined by Gated-SPECT. Considering that, it’s difficult to carry out this analysis in real patients. For ethical, logistical and economical matters, simulated studies could be required for this analysis. Objective: Evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters (LVEF – left ventricular ejection fraction, EDV – end-diastolic volume, ESV – end-sistolic volume) using routine software procedures.por
dc.identifier.citationVieira L, Sousa E, Vaz T, Costa DC, Almeida P. Study of the influence of count’s number in myocardium in the determination of reproducible functional parameters in Gated-SPECT studies simulated with GATE. In EANM'2012 - Annual Congress of European Association of Nuclear Medicine, Milan (Italy), 27th-30th October 2012. Poster.por
dc.identifier.urihttp://hdl.handle.net/10400.21/2512
dc.language.isoengpor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://eanm12.eanm.org/abstracts/session_detail.php?sessionNumber=TP01&referer=/programme/poster_exh.php?navId=18&progNavId=36por
dc.subjectNuclear medicinepor
dc.subjectMyocardiumpor
dc.subjectGated-SPECTpor
dc.subjectLeft ventricular ejection fractionpor
dc.subjectEnd-diastolic volumepor
dc.subjectEnd-sistolic volumepor
dc.titleStudy of the influence of count’s number in myocardium in the determination of reproducible functional parameters in Gated-SPECT studies simulated with GATEpor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceMilãopor
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Study of the influence of count’s number in myocardium.pdf
Size:
155.46 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections