Repository logo
 
Publication

The impact of pitch values on image quality and radiation dose in an abdominal adult phantom using CT

dc.contributor.authorLança, Luís
dc.contributor.authorBarros, Pietro
dc.contributor.authorD'Agostini Derech, Rodrigo
dc.contributor.authorHiggins, Daniel
dc.contributor.authorKleiker, Marjolein
dc.contributor.authorLiardet, Sébastien
dc.contributor.authorLøvlien, Ine Michaela
dc.contributor.authorMcNally, Kevin
dc.contributor.authorThévenaz, Manon
dc.contributor.authorHogg, Peter
dc.date.accessioned2017-03-07T15:55:25Z
dc.date.available2017-03-07T15:55:25Z
dc.date.issued2017-03
dc.description.abstractDifferent parameters on CT can be used to reduce the patient radiation dose. One of these parameters is pitch, which is defined as the table movement per 360 degrees rotation time divided by the beam width. The use of a high pitch can reduce the radiation dose and the scan time. When the CT scan is acquired within a shorter time, possible motion artefacts can be reduced. This is useful when scanning areas in which there is a lot of involuntary movement, such as the cardiac and lung regions. However, it is important to consider the effect of a higher pitch on image quality, particularly on the spatial resolution. On the other hand, a low pitch might be chosen when high image quality is needed. Consideration has to be made when deciding whether the effective radiation dose counterbalances the image quality. This study aims to identify the impact of pitch on image quality and effective dose for axial and coronal planes in abdominal adult CT.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationLança L, Barros P, D'Agostini Derech R, Higgins D, Kleiker MA, Liardet S, et al. The impact of pitch values on image quality and radiation dose in an abdominal adult phantom using CT. In: ECR 2017 – European Congress of Radiology, Vienna, March 1-5, 2017.pt_PT
dc.identifier.doi10.1594/ecr2017/C-2755pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/6844
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.relation.publisherversionhttp://posterng.netkey.at/esr/viewing/index.php?module=viewing_poster&task=&pi=139504&searchkeypt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectRadiologypt_PT
dc.subjectRadiographerpt_PT
dc.subjectAbdomenpt_PT
dc.subjectRadioprotectionpt_PT
dc.subjectRadiation dosept_PT
dc.subjectCTpt_PT
dc.subjectComputer applicationspt_PT
dc.subjectEducation and trainingpt_PT
dc.titleThe impact of pitch values on image quality and radiation dose in an abdominal adult phantom using CTpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceVienapt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
The impact of pitch values on image quality and radiation dose in an abdominal adult phantom using CT.pdf
Size:
577.83 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections