Repository logo
 
Publication

Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment

dc.contributor.authorVarella, Roberto Aliandro
dc.contributor.authorGiechaskiel, Barouch
dc.contributor.authorSousa, Luís
dc.contributor.authorDuarte, Gonçalo
dc.date.accessioned2018-10-10T13:34:29Z
dc.date.available2018-10-10T13:34:29Z
dc.date.issued2018-09-12
dc.description.abstractReal-driving emissions (RDE) testing with portable emissions measurement systems (PEMS) during the type approval and in-service conformity of light-duty vehicles was recently introduced in the European Union legislation. In this paper, three PEMS were compared with laboratory analyzers connected to the tailpipe and the dilution tunnel. The tests were conducted with two Euro 6 vehicles (one gasoline and one diesel) performing the World harmonized Light vehicles Test Cycle (WLTC) and a pre-recorded RDE cycle on a chassis dynamometer. The results showed that the differences of the PEMS gas analyzers compared to the laboratory references were typically within 2% for CO2 and 5% for NOx. The CO2 and NOx mass emissions were within 10% and 15%, respectively, with only a few exceptions. The exhaust flow rate measurements were within 10% at low speeds (urban conditions), and 5% at higher speeds. These results confirm the legislated permitted tolerances and the 2017 PEMS uncertainty estimates.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationVARELLA, Roberto Aliandro; [et al] – Comparison of Portable Emissions Measurement Systems (PEMS) with Laboratory Grade Equipment. Applied Sciences - Basel. ISSN 2076-3417. Vol. 8, N.º 9 (2018), pp. 1-12pt_PT
dc.identifier.doi10.3390/app8091633pt_PT
dc.identifier.issn2076-3417
dc.identifier.urihttp://hdl.handle.net/10400.21/8906
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherMDPIpt_PT
dc.subjectPortable emissions measurement system (PEMS)pt_PT
dc.subjectWorldwide harmonized light vehicles test cycle (WLTC)pt_PT
dc.subjectReal driving emissions (RDE)pt_PT
dc.subjectConformity factor (CF)pt_PT
dc.subjectValidation testpt_PT
dc.subjectCO2pt_PT
dc.subjectNOxpt_PT
dc.subjectExhaust flow meter (EFM)pt_PT
dc.subjectMeasurement uncertaintypt_PT
dc.titleComparison of portable emissions measurement systems (PEMS) with laboratory grade equipmentpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage12pt_PT
oaire.citation.issue9pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.titleApplied Sciences - Baselpt_PT
oaire.citation.volume8pt_PT
person.familyNameGiechaskiel
person.familyNameSousa
person.familyNameDuarte
person.givenNameBarouch
person.givenNameLuis
person.givenNameGonçalo
person.identifier.ciencia-id5414-D855-E2F5
person.identifier.ciencia-id6918-836F-646D
person.identifier.orcid0000-0002-8917-1660
person.identifier.orcid0000-0002-0575-4894
person.identifier.orcid0000-0002-7216-611X
person.identifier.ridI-1242-2014
person.identifier.scopus-author-id7004775542
person.identifier.scopus-author-id57189656488
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication406ac5bd-c85e-485a-9b4a-6802fac9e152
relation.isAuthorOfPublication8e34560d-3df4-4c14-a02f-b6940cbd9433
relation.isAuthorOfPublication060bb526-9d2c-4717-91dc-2f91262667c7
relation.isAuthorOfPublication.latestForDiscovery406ac5bd-c85e-485a-9b4a-6802fac9e152

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Comparison_GDuarte_ADEM.pdf
Size:
3.3 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: