Is the quantitative cut-off a suitable surrogate to ensure a good indoor air quality regarding the mycobiota in health care facilities?

dc.contributor.authorViegas, Carla
dc.contributor.authorAlmeida, B.
dc.date.accessioned2019-03-22T13:20:54Z
dc.date.available2019-03-22T13:20:54Z
dc.date.issued2019-02
dc.descriptionEXPOsE—Establishing protocols to assess occupational exposure to microbiota in clinical settings (02/SAICT/2016 - Project nº 23222).pt_PT
dc.description.abstractControl measures are crucial in clinical environments for reducing concentrations of airborne fungal and, consequently, to avoid invasive infections acquired from indoor air. This study intends to assess mycobiota in 10 Primary Health Care Centers (PHCC) applying the Indoor Air Quality Portuguese legislation as guidance. After the quantitative cut-off analyses (ratio between indoor and outdoor load (I/O)) the fungal species identification was performed to verify if the fungal conformity was achieved. A fungal assessment was realized by air samples through an impaction device and consisted mainly of one indoor sample in each sampling location and one outdoor sample, to be used as a reference. Among the 10 PHCC, 60% (6 out of 10) presented I/O > 1. However, in two PHCC that comply with the quantitative cut-off toxigenic species were identified. The quantitative cut-off applied to assess IAQ is not a suitable surrogate to ensure good air quality and qualitative assessment should always be performed to guarantee an accurate assessment.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationViegas C, Almeida B. Is the quantitative cut-off a suitable surrogate to ensure a good indoor air quality regarding the mycobiota in health care facilities? In: Arezes P, et al., editors. Occupational and environmental safety and health – Studies in systems, decision and control (Vol. 202). Cham: Springer; 2019. p. 355-61.pt_PT
dc.identifier.doi10.1007/978-3-030-14730-3_38pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/9752
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSpringerpt_PT
dc.relationEXPOsE—Establishing protocols to assess occupational exposure to microbiota in clinical settingspt_PT
dc.relation02/SAICT/2016 - Project nº 23222pt_PT
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007%2F978-3-030-14730-3_38pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectOccupational healthpt_PT
dc.subjectOccupational exposurept_PT
dc.subjectHealth care facilitiespt_PT
dc.subjectIndoor airpt_PT
dc.subjectPrimary health care centerpt_PT
dc.subjectAir qualitypt_PT
dc.subjectPortugalpt_PT
dc.subjectProject nº 23222 (02/SAICT/2016)pt_PT
dc.titleIs the quantitative cut-off a suitable surrogate to ensure a good indoor air quality regarding the mycobiota in health care facilities?pt_PT
dc.typebook part
dspace.entity.typePublication
oaire.citation.endPage361pt_PT
oaire.citation.startPage355pt_PT
person.familyNameViegas
person.givenNameCarla
person.identifier.ciencia-idEE1E-C639-D70F
person.identifier.orcid0000-0002-1545-6479
person.identifier.ridB-7217-2013
person.identifier.scopus-author-id55443609700
rcaap.rightsrestrictedAccesspt_PT
rcaap.typebookPartpt_PT
relation.isAuthorOfPublicationb5fa5da4-50c3-4b88-ae20-1bc63cb485f7
relation.isAuthorOfPublication.latestForDiscoveryb5fa5da4-50c3-4b88-ae20-1bc63cb485f7

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
Is the quantitative cut-off a suitable surrogate to ensure a good indoor air quality regarding the mycobiota in health care facilities.pdf
Tamanho:
153.39 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: