Repository logo
 
Publication

Consumo energético e eficiência da marcha com dois modelos de joelhos protésicos: estudo de caso

dc.contributor.authorSá, Catarina
dc.contributor.authorCruz, Joana
dc.contributor.authorNascimento, Rafael
dc.contributor.authorSilva, José Maurício
dc.contributor.authorTomás, Maria Teresa
dc.date.accessioned2012-01-02T15:46:39Z
dc.date.available2012-01-02T15:46:39Z
dc.date.issued2011-11
dc.description.abstractIntrodução – Os componentes protésicos têm um papel fundamental na eficiência energética da marcha dos indivíduos amputados. Esta é uma área de conhecimento ainda em desenvolvimento, onde a investigação desempenha um papel central. Objectivos – Comparar e analisar o efeito de dois joelhos protésicos, 3R34, monocêntrico modular, de fricção constante, com auxiliar de extensão incorporado (A) e 3R92, monocêntrico modular, com travão de fricção e controlo pneumático da fase de balanço (B) no consumo energético e eficiência da marcha. Metodologia – Um indivíduo do sexo masculino de 27 anos, com amputação transfemural longa, foi sujeito a um protocolo submáximo de avaliação da resposta ao exercício em passadeira rolante (H/P/Cosmos(R) Mercury), através de um sistema de análise de gases breath‑by‑breath (Cosmed Quark PFT Ergo). Foi efetuado o mesmo protocolo com intervalo de dois dias, primeiro utilizando o joelho A e depois o B. As variáveis analisadas foram o consumo de O2 (VO2), o equivalente metabólico (MET) e a eficiência energética da marcha (Quociente de VO2 esperado de um individuo saudável e o VO2 do individuo em estudo). O esforço percecionado foi medido com a escala RPE de Borg. Resultados – O consumo energético com o joelho A (24,2 ml O2/kg/min; 6,9 MET) foi inferior ao obtido com o joelho B (28,68 ml O2/kg/min; 8,2 MET). A eficiência energética da marcha foi mais elevada para o joelho A (43%) do que para o joelho B (39%). Conclusão – A utilização do joelho A na prótese do indivíduo em estudo resulta numa marcha de menor consumo energético e maior eficiência. No entanto, este valor poderá estar influenciado pelo curto período de adaptação ao joelho B, sendo necessários mais estudos para confirmar os resultados do estudo e a influência deste fator. ABSTRACT - Background – Prosthetic components have a crucial role in the energy efficiency of amputee’s gait. This is an area of knowledge still in development, where research plays a central role. Objective – The purpose of this case study is to compare the impact in energy consumption of two prosthetic knees, titanium single‑axis constant friction knee joint with internal extension assist, 3R34 (A) and a single‑axis pneumatic swing phase control, 3R92 (B). Methodology – The participant was a transtibial amputee, male, with 27 years old, with no other clinical or functional impairments. To measure the energy expenditure a submaximal treadmill (H/P/Cosmos(R) Mercury) exercise stress test combined with a breath‑by‑breath analysis system (Cosmed Quark PFT Ergo) was used. The same test was applied to both knees, separated by two days. The analyzed variables were O2 consumption (VO2), metabolic equivalent (MET) and gait efficiency (VO2 ratio expected from a healthy individual and the studied individual). A rate of perceived exertion (Borg’s Scale) was used. Results – The results were favorable to knee A (24.2 ml O2/kg/min; 6.9 MET, 43% efficiency) compared with knee B (28.68 ml O2/kg/min; 8.2 MET, 39% efficiency). Conclusion – In this case, a less energy consumption gait corresponds to the prosthesis with knee A. These values may be influenced by the short adaptation period with knee B, so it’s necessary to perform more studies to confirm the previous results and to understand the truly impact of correct adaptation factor to the best prosthetics components for different patients.por
dc.identifier.citationSá C, Cruz J, Nascimento R, Silva, JM, Tomás MT. Consumo energético e eficiência da marcha com dois modelos de joelhos protésicos: estudo de caso. Saúde & Tecnologia. 2011;(6):38-43.por
dc.identifier.issn1646-9704
dc.identifier.urihttp://hdl.handle.net/10400.21/987
dc.language.isoporpor
dc.peerreviewedyespor
dc.publisherEscola Superior de Tecnologia da Saúde de Lisboapor
dc.subjectConsumo de oxigéniopor
dc.subjectJoelho mecânicopor
dc.subjectAmputação transfemuralpor
dc.subjectConsumo energéticopor
dc.subjectEficiência energéticapor
dc.subjectOrtoprotesiapor
dc.subjectO2 consumptionpor
dc.subjectMechanical prosthetic kneepor
dc.subjectTransfemural amputationpor
dc.subjectEnergy expenditurepor
dc.subjectGait efficiencypor
dc.subjectProstheticspor
dc.titleConsumo energético e eficiência da marcha com dois modelos de joelhos protésicos: estudo de casopor
dc.title.alternativeGait energy consumption and gait efficiency with two different models of prosthetics knees: a single case reportpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage43por
oaire.citation.startPage38por
oaire.citation.titleSaúde & Tecnologiapor
person.familyNameTomás
person.givenNameMaria Teresa
person.identifier438585
person.identifier.ciencia-id3010-19D6-C7A5
person.identifier.orcid0000-0003-0491-8903
person.identifier.ridN-1940-2013
person.identifier.scopus-author-id36700434200
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication64ad74a4-4cd4-426e-a1ee-2ec846fdc6dd
relation.isAuthorOfPublication.latestForDiscovery64ad74a4-4cd4-426e-a1ee-2ec846fdc6dd

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
S&T6_art6.pdf
Size:
315.03 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections