A new control strategy with saturation effect compensation for an autonomous induction generator drivenby wide speed range turbines

dc.contributor.authorMargato, Elmano
dc.contributor.authorFaria, José
dc.contributor.authorResende, M. J.
dc.contributor.authorPalma, João Carlos Pires da
dc.date.accessioned2013-01-25T12:19:20Z
dc.date.available2013-01-25T12:19:20Z
dc.date.issued2011-05
dc.description.abstractThis paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.por
dc.identifier.citationMARGATO, Elmano; FARIA, José; RESENDE, M. J.; PALMA, João - A new control strategy with saturation effect compensation for an autonomous induction generator drivenby wide speed range turbines. Energy Conversion and Management. ISSN 0196-8904. Vol. 52, n.º 5 (2011) p. 2142-2152.por
dc.identifier.issn0196-8904
dc.identifier.urihttp://hdl.handle.net/10400.21/2066
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherPergamon-Elsevier Science LTDpor
dc.subjectAutonomous Induction Generatorpor
dc.subjectMagnetic Saturation Effectpor
dc.subjectMicro-Hydro Power Plantspor
dc.subjectRotor Flux Oriented Controlpor
dc.subjectStatic Var Excitationpor
dc.titleA new control strategy with saturation effect compensation for an autonomous induction generator drivenby wide speed range turbinespor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceOxfordpor
oaire.citation.endPage2152por
oaire.citation.issue5por
oaire.citation.startPage2142por
oaire.citation.titleEnergy Conversion and Managementpor
oaire.citation.volume52por
person.familyNameMargato
person.givenNameElmano
person.identifier.ciencia-id2F12-3295-B091
person.identifier.orcid0000-0002-8601-9145
person.identifier.scopus-author-id6505972972
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication9f983bef-f0ef-4660-b6e9-e9beebaf6acc
relation.isAuthorOfPublication.latestForDiscovery9f983bef-f0ef-4660-b6e9-e9beebaf6acc

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
A new control strategy with saturation effect compensation for an autonomous induction generator drivenby wide speed range turbines.rep.pdf
Size:
196.28 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
A new control.pdf
Size:
783.83 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: