Publication
Exposição ocupacional em contexto de radiologia de intervenção: avaliação da radiação dispersa em procedimentos padrão
authorProfile.email | biblioteca@isel.pt | |
dc.contributor.advisor | Ribeiro, Maria Margarida do Carmo Pinto | |
dc.contributor.advisor | Borges, Cecília Odete Paulos | |
dc.contributor.author | Costa, Tomás Daniel Van Driel | |
dc.date.accessioned | 2025-02-28T14:24:10Z | |
dc.date.available | 2025-02-28T14:24:10Z | |
dc.date.issued | 2024-12 | |
dc.description | Dissertação para obtenção do grau de Mestre em Engenharia Biomédica | |
dc.description.abstract | Os procedimentos de diagnóstico e intervenção guiados por fluoroscopia envolvem frequentemente elevados tempos de exposição podendo resultar em doses ocupacionais consideráveis, ambos para o paciente, como para os trabalhadores expostos caso não sejam tomadas medidas adequadas à redução da sua exposição. Atualmente, existe um crescente recurso a este tipo de procedimentos na prática clínica, no entanto, as doses de radiação administradas aos pacientes e, consequentemente aos trabalhadores, são motivo de acrescida monitorização devido aos riscos associados aos crescentes níveis de exposição ocupacional. Os Safety standards da IAEA fornecem recomendações e orientações sobre como cumprir os requisitos de segurança, indicando as medidas aconselhadas que refletem as melhores práticas para ajudar as instituições empenhadas em alcançar elevados níveis de segurança, sendo que uma das quais é a quantificação da radiação dispersa e a aplicação das boas práticas clínicas. O presente estudo de investigação foca-se na quantificação e otimização dos níveis de dose de radiação dispersa aos quais os trabalhadores são expostos em três procedimentos de radiologia de intervenção de uma instituição de Saúde. Foram selecionados os procedimentos de Cateterismo Cardíaco, com e sem posterior Angioplastia, a Ablação Cardíaca via radiofrequência ou crioablação e a Dacriocistografia, cuja seleção se sustentou na análise do risco que estes apresentam. O risco associado a estes foi estimado pela frequência a que são realizados, os tempos médios de exposição e as doses ocupacionais tipicamente observadas. De forma a identificar mecanismos de otimização, foi criada uma caracterização de cenários-padrão do fluxo de trabalho de procedimentos reais e desenvolvido um modelo de avaliação da exposição ocupacional baseado em medições da dose dispersa na sala com recurso a fantomas antropomórficos. Os resultados deste estudo permitiram o desenvolvimento de fatores de correlação entre o DAP total do procedimento e a dose ocupacional estimada para cada trabalhador exposto. | por |
dc.description.abstract | Abstract Diagnostic and interventional procedures guided by fluoroscopy often involve high exposure times and can result in considerable occupational doses, both for the patient and the exposed workers if appropriate measures are not taken to reduce their exposure. Currently, there is a growing use of this type of procedure in clinical practice, however, the doses of radiation administered to patients and, consequently, to workers, are cause for increased monitoring due to the risks associated with increasing levels of occupational exposure. The IAEA Safety standards provide recommendations and guidance on how to meet safety requirements, indicating recommended measures that reflect best practice to help institutions striving to achieve high levels of safety, one of which is the quantification of scattered radiation and the application of good clinical practice. This research study focuses on quantifying and optimizing the dose levels of scattered radiation to which workers are exposed in three different interventional radiology procedures at a healthcare institution. Cardiac catheterization procedures, with and without subsequent angioplasty, cardiac ablation via radiofrequency or cryoablation and dacryocystography were selected based on the analysis of the risk they present. The associated risk was estimated by the frequency with which they are performed, the average exposure times and the occupational doses typically observed. As to identify optimization mechanisms with a view of reducing occupational exposure, a characterization of standard workflow scenarios during real procedures was created and an occupational exposure assessment model was developed based on scattered dose measurements in the room using anthropomorphic phantoms. The results of this study made it possible to develop correlation factors between the total DAP of the procedure and the estimated occupational dose for each exposed worker. | eng |
dc.identifier.citation | COSTA, Tomás Daniel Van Driel – Exposição ocupacional em contexto de radiologia de intervenção: avaliação da radiação dispersa em procedimentos padrão. Lisboa: Instituto Superior de Engenharia de Lisboa. 2024. Dissertação de Mestrado. | |
dc.identifier.tid | 203797485 | |
dc.identifier.uri | http://hdl.handle.net/10400.21/21619 | |
dc.language.iso | por | |
dc.peerreviewed | yes | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Fluoroscopia | |
dc.subject | Dosimetria | |
dc.subject | Radiação ionizante | |
dc.subject | Radiologia de intervenção | |
dc.subject | Fluoroscopy | |
dc.subject | Dosimetry | |
dc.subject | Ionizing radiation | |
dc.subject | Interventional radiology | |
dc.title | Exposição ocupacional em contexto de radiologia de intervenção: avaliação da radiação dispersa em procedimentos padrão | por |
dc.type | master thesis | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 78 | |
oaire.citation.startPage | 1 | |
oaire.version | http://purl.org/coar/version/c_be7fb7dd8ff6fe43 |