Repository logo
 
Publication

Lesion detection performance in an anthropomorphic chest phantom: comparative analysis of low-dose CT data on two hybrid imaging systems

dc.contributor.authorJessop, M.
dc.contributor.authorThompson, John D.
dc.contributor.authorCoward, J.
dc.contributor.authorSanderud, Audun
dc.contributor.authorJorge, José
dc.contributor.authorde Groot, M.
dc.contributor.authorLança, Luís
dc.contributor.authorHogg, Peter
dc.date.accessioned2015-08-21T15:40:27Z
dc.date.available2015-08-21T15:40:27Z
dc.date.issued2014-06
dc.description.abstractIntroduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.por
dc.identifier.citationJessop M, Thompson JD, Sanderud A, Jorge J, Lança L, Hogg P, et al. Lesion detection performance in an anthropomorphic chest phantom: comparative analysis of low-dose CT data on two hybrid imaging systems. In Proceedings of International Society of Radiographer and Radiological Technologists, Helsinki (Finland), FIN, 12th to 15th June 2014.por
dc.identifier.isbn9789526707433
dc.identifier.urihttp://hdl.handle.net/10400.21/4917
dc.language.isoengpor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://portfolio-web.ess.fi/www/SuomenRontgenhoitajat/2014_ISRRT/#/1/por
dc.subjectRadiologypor
dc.subjectImaging systempor
dc.subjectAnthropomorphic chestpor
dc.subjectPhantompor
dc.subjectDosimetrypor
dc.titleLesion detection performance in an anthropomorphic chest phantom: comparative analysis of low-dose CT data on two hybrid imaging systemspor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceHelsínquiapor
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Lesion detection performance in an anthropomorphic chest phantom.pdf
Size:
2.85 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: