Repository logo
 
Publication

Validation of a new reference values’s database for semiquantification of 123I‐FP‐CIT SPECT scans in one nuclear medicine department

dc.contributor.authorElias, Madalena
dc.contributor.authorQueiroga, Margarida
dc.contributor.authorSilva, Diana
dc.contributor.authorSerrado, José
dc.contributor.authorMadrid, José
dc.contributor.authorCarolino, Elisabete
dc.contributor.authorSousa, Eva
dc.date.accessioned2015-11-04T14:51:35Z
dc.date.available2015-11-04T14:51:35Z
dc.date.issued2015-10
dc.description.abstractThe DatScanTM and its Semiquantification (SQ) can provide advantages in the diagnosis of Parkinsonian Syndromes (PS). To improve the SQ is recommended the creation of adapted database (DB) with reference values for the Nuclear Medicine Departments. Previously to this work was created a adapted database (DBRV) to Nuclear Medicine Department's protocol and population of Infanta Cristina's Hospital located in Badajoz, for patients between the ages of 60 and 75, and reference values of the SQ were calculated. Aim: To evaluate the discrimination capacity of a department's adapted DB reference's values of healthy controls for DatScanTM.pt_PT
dc.identifier.citationElias M, Queiroga M, Silva D, Serrado J, Carolino E, Sousa E, et al. Validation of a new reference values’s database for semiquantification of 123I‐FP‐CIT SPECT scans in one nuclear medicine department. In EANM'15 – Annual Congress of the European Association of Nuclear Medicine, Hamburg (Germany), October 10-14, 2015.pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/5348
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.relation.publisherversionhttp://eanm15.eanm.org/programme/docs/FINAL_EANM15_CTE_ABSTRACT_BOOK.pdfpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectNuclear medicinept_PT
dc.subjectReference values databasept_PT
dc.subject123I‐FP‐CITpt_PT
dc.subjectSPECTpt_PT
dc.subjectSpainpt_PT
dc.titleValidation of a new reference values’s database for semiquantification of 123I‐FP‐CIT SPECT scans in one nuclear medicine departmentpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceHamburgopt_PT
person.familyNameCarolino
person.givenNameElisabete
person.identifier.ciencia-id1216-EFA3-1E0F
person.identifier.orcid0000-0003-4165-7052
person.identifier.ridF-1012-2015
person.identifier.scopus-author-id25821697000
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication77930d39-ed34-44dc-a4a6-9bf833e5e688
relation.isAuthorOfPublication.latestForDiscovery77930d39-ed34-44dc-a4a6-9bf833e5e688

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Validation of a new reference values’s database for semiquantification of 123I‐FP‐CIT SPECT scans in one nuclear medicine department.pdf
Size:
366.27 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections