Repository logo
 
Publication

Patient safety culture in Portuguese dentistry: instrument validity and reliability

dc.contributor.authorFigueira, Catarina
dc.contributor.authorBizarra, Fátima
dc.contributor.authorEiras, Margarida
dc.contributor.authorSilva, Carina
dc.date.accessioned2022-07-21T09:55:03Z
dc.date.available2022-07-21T09:55:03Z
dc.date.issued2022-07
dc.description.abstractObjetivos: Este estudo teve como objetivo adaptar, validar e analisar a fiabilidade do Medical Office Survey on Patient Safety Culture (MOSPSC) para os cuidados de medicina dentária em Portugal. Métodos: A versão portuguesa do MOSPSC, da Agency for Healthcare Research and Quality (AHRQ), foi adaptada para os cuidados de medicina dentária em Portugal. Seis especialistas foram responsáveis pela análise semântica e validade de conteúdo. Para a análise de fiabilidade foi calculado o alfa de Cronbach e a average inter-item correlation (AIIC). A análise fatorial confirmatória (AFC) avaliou a qualidade do ajustamento do modelo associado ao modelo teórico proposto pela AHRQ. Os testes de ajustamento utilizados foram o quociente entre o qui-quadrado e o número de graus de liberdade (χ2/df), o índice goodness-of-fit (GFI), o índice comparative fit (CFI), o índice Tucker-Lewis (TLI), o parsimony GFI e o índice root mean square error of approximation (RMSEA). Resultados: Na amostra inicial procedeu-se à análise de valores omissos, resultando numa amostra final de 143 participantes. O modelo proposto pela AFC correspondeu à junção de dois pares de dimensões (dimensões “comunicação acerca do erro” e “abertura na comunicação”; “processos e padronização” e “pressão e ritmo de trabalho”). O modelo proposto obteve uma boa consistência global (alfa de Cronbach α=0,93; AIIC=0,27) e um ajustamento global moderado face à amostra em estudo (χ2/df=5,63; GFI=0,90; CFI=0,90; TLI=0,88; PGFI=0,67; RMSEA=0,18; p<0,001; IC de 90% RMSEA [0,175;0,186]). Conclusões: A estrutura do modelo proposto resultou em oito dimensões, que obtiveram uma boa fiabilidade e uma validade de constructo moderada.pt_PT
dc.description.abstractABSTRACT - Objectives: The purpose of this study was to adapt, validate, and analyze the reliability of the Medical Office Survey on Patient Safety Culture (MOSPSC) for Portuguese dental care. Methods: The Portuguese version of the MOSPSC of the Agency for Healthcare Research and Quality (AHRQ) was adapted for Portuguese dental care. Six specialists conducted the content validity and semantic analysis. The reliability analysis was performed using Cronbach’s alpha and average inter-item correlation (AIIC). Confirmatory factor analysis (CFA) was conducted to assess the fit quality of the model associated with the theoretical model proposed by the AHRQ. The following goodness-of-fit indexes were used: the quotient between chisquare and the number of degrees of freedom (χ2/df), the goodness-of-fit index (GFI), the comparative fit index (CFI), the Tucker-Lewis index (TLI), Parsimony GFI, and the root mean square error of approximation index (RMSEA). Results: The initial sample (n=237) was subjected to an analysis of missing values, resulting in a final sample of 143 participants. The model proposed by the CFA corresponded to the joining of two pairs of dimensions (“communication about error” and “communication openness” dimensions; “office processes and standardization” and “work pressure and pace” dimensions). The proposed model obtained good overall consistency (Cronbach’s α=0.93; AIIC=0.27) and moderate overall fit considering the study sample (χ2/df=5.63; GFI=0.90; CFI=0.90; TLI=0.88; PGFI=0.67; RMSEA=0.18; p<0.001; 90% CI RMSEA [0.175;0.186]). Conclusions: The proposed model structure resulted in eight dimensions, which achieved good reliability and moderate construct validity.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationFigueira C, Bizarra F, Eiras M, Silva C. Patient safety culture in Portuguese dentistry: Instrument validity and reliability. Rev Port Estomatol Med Dent Cir Maxilofac. 2022;63(2):68-75.pt_PT
dc.identifier.doi10.24873/j.rpemd.2022.06.872pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.21/14860
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSociedade Portguesa de Estomatologia e Medicina Dentáriapt_PT
dc.relation.publisherversionhttps://revista.spemd.pt/article/1816#!pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectDentistrypt_PT
dc.subjectPatient safetypt_PT
dc.subjectSafety culturept_PT
dc.subjectReliabilitypt_PT
dc.subjectValiditypt_PT
dc.subjectPortugalpt_PT
dc.subjectMedicina dentáriapt_PT
dc.subjectSegurança do doentept_PT
dc.subjectCultura de segurançapt_PT
dc.subjectFiabilidadept_PT
dc.subjectValidadept_PT
dc.titlePatient safety culture in Portuguese dentistry: instrument validity and reliabilitypt_PT
dc.title.alternativeCultura de segurança do doente na medicina dentária portuguesa: validade e fiabilidade do instrumentopt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage75pt_PT
oaire.citation.issue2pt_PT
oaire.citation.startPage68pt_PT
oaire.citation.titleRevista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacialpt_PT
oaire.citation.volume63pt_PT
person.familyNameSilva
person.givenNameCarina
person.identifier.ciencia-id2411-5936-0820
person.identifier.orcid0000-0003-1021-7935
person.identifier.scopus-author-id55258764900
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication81a5cd80-1982-43ba-bde5-4c43ae0e5234
relation.isAuthorOfPublication.latestForDiscovery81a5cd80-1982-43ba-bde5-4c43ae0e5234

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Patient safety culture in Portuguese dentistry_instrument validity and reliability.pdf
Size:
350.16 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections