dc.description.abstract | In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal. | por |
dc.identifier.citation | Machado N, Carvoeiras P, Teixeira N. Results of radiation protection programmes on mammography. Radiat Prot Dosimetry. 2005;116(1-4 Pt 2):624-6. | por |
dc.identifier.issn | 1742-3406 | |
dc.identifier.uri | http://hdl.handle.net/10400.21/2988 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Oxford University Press | por |
dc.relation.publisherversion | http://rpd.oxfordjournals.org/content/116/1-4/624.abstract | por |
dc.subject | Algorithms | por |
dc.subject | Mammography | por |
dc.subject | Phantoms, Imaging | por |
dc.subject | Radiation protection | por |
dc.subject | Radiographic image enhancement | por |
dc.subject | Radiographic image interpretation | por |
dc.subject | Reproducibility of results | por |
dc.subject | Sensitivity and specificity | por |
dc.title | Results of radiation protection programmes on mammography | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 626 | por |
oaire.citation.startPage | 624 | por |
oaire.citation.title | Radiation Protection Dosimetry | por |
oaire.citation.volume | 116 | por |
rcaap.rights | restrictedAccess | por |
rcaap.type | article | por |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Results of radiation protection programmes on mammography.pdf
- Size:
- 103.44 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: