Repository logo
 
Publication

Results of radiation protection programmes on mammography

dc.contributor.authorMachado, Nuno
dc.contributor.authorCarvoeiras, Pedro
dc.contributor.authorTeixeira, Nuno
dc.date.accessioned2013-12-11T14:45:30Z
dc.date.available2013-12-11T14:45:30Z
dc.date.issued2005-12
dc.description.abstractIn this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.por
dc.identifier.citationMachado N, Carvoeiras P, Teixeira N. Results of radiation protection programmes on mammography. Radiat Prot Dosimetry. 2005;116(1-4 Pt 2):624-6.por
dc.identifier.issn1742-3406
dc.identifier.urihttp://hdl.handle.net/10400.21/2988
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherOxford University Presspor
dc.relation.publisherversionhttp://rpd.oxfordjournals.org/content/116/1-4/624.abstractpor
dc.subjectAlgorithmspor
dc.subjectMammographypor
dc.subjectPhantoms, Imagingpor
dc.subjectRadiation protectionpor
dc.subjectRadiographic image enhancementpor
dc.subjectRadiographic image interpretationpor
dc.subjectReproducibility of resultspor
dc.subjectSensitivity and specificitypor
dc.titleResults of radiation protection programmes on mammographypor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage626por
oaire.citation.startPage624por
oaire.citation.titleRadiation Protection Dosimetrypor
oaire.citation.volume116por
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Results of radiation protection programmes on mammography.pdf
Size:
103.44 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections