Repository logo
 
Publication

Prevalence of fungi in indoor air with reference to gymnasiums with swimming pools

dc.contributor.authorViegas, Carla
dc.contributor.authorAlves, Célia
dc.contributor.authorCarolino, Elisabete
dc.contributor.authorRosado, Laura
dc.contributor.authorSantos, Carlos Silva
dc.date.accessioned2011-12-20T16:15:18Z
dc.date.available2011-12-20T16:15:18Z
dc.date.issued2010
dc.description.abstractFungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).por
dc.identifier.citationViegas C, Alves C, Carolino E, Rosado L, Santos CS. Prevalence of fungi in indoor air with reference to gymnasiums with swimming pools. Indoor Built Environ. 2010;19(5):555-61.por
dc.identifier.issn1423-0070
dc.identifier.urihttp://hdl.handle.net/10400.21/945
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSagepor
dc.relation.publisherversionhttp://ibe.sagepub.com/content/19/5/555por
dc.subjectSaúde ambientalpor
dc.subjectSaúde ocupacionalpor
dc.subjectHumidadepor
dc.subjectTemperaturapor
dc.subjectGinásiopor
dc.subjectPiscinapor
dc.subjectEnvironmental variablespor
dc.subjectFungal contaminationpor
dc.subjectGymnasiumpor
dc.subjectHumiditypor
dc.subjectSwimming poolpor
dc.subjectTemperaturepor
dc.titlePrevalence of fungi in indoor air with reference to gymnasiums with swimming poolspor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage561por
oaire.citation.startPage555por
person.familyNameViegas
person.familyNameCarolino
person.givenNameCarla
person.givenNameElisabete
person.identifier.ciencia-idEE1E-C639-D70F
person.identifier.ciencia-id1216-EFA3-1E0F
person.identifier.orcid0000-0002-1545-6479
person.identifier.orcid0000-0003-4165-7052
person.identifier.ridB-7217-2013
person.identifier.ridF-1012-2015
person.identifier.scopus-author-id55443609700
person.identifier.scopus-author-id25821697000
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublicationb5fa5da4-50c3-4b88-ae20-1bc63cb485f7
relation.isAuthorOfPublication77930d39-ed34-44dc-a4a6-9bf833e5e688
relation.isAuthorOfPublication.latestForDiscovery77930d39-ed34-44dc-a4a6-9bf833e5e688

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Prevalence of fungi in indoor air with reference to gymnasiums with swimming pools1.pdf
Size:
183.43 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections