Effects of broken skirts and pollution on voltage distribution for cap and pin glass insulators

dc.contributor.authorMateus, C.
dc.contributor.authorBarata, Filipe
dc.contributor.authorLuís, Ricardo
dc.date.accessioned2020-09-03T13:30:07Z
dc.date.available2020-09-03T13:30:07Z
dc.date.issued2020-08-07
dc.description.abstractCap and Pin insulators are key elements on aerial electric power transmission lines in which their performance is subject to the environmental elements, like pollution and/or humidity. Furthermore, a broken insulator (stub) on an insulator string may change the voltage distribution along the chain. This paper goal is to study the effects of the voltage distribution along with tempered glass cap and pin insulator string in the presence of broken skirts as well contamination by pollution, using for that purpose a finite element software. This paper presents the voltage distribution profile across single and fourteen units of glass insulator string with stubs at distinct locations as well for the presence of contamination by pollution. It is concluded that the presence of pollution on a string with stubs will alter and exacerbate the increase of electrical potential effect due to the presence of stubs.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationMATEUS, C.; BARATA, F. A.; LUÍS, Ricardo – Effects of broken skirts and pollution on voltage distribution for cap and pin glass insulators. In 2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG). Setúbal, Portugal: IEEE, 2020. ISBN 978-1-7281-4218-0. Pp. 30-35pt_PT
dc.identifier.doi10.1109/CPE-POWERENG48600.2020.9161644pt_PT
dc.identifier.isbn978-1-7281-4218-0
dc.identifier.isbn978-1-7281-4219-7
dc.identifier.issn2166-9546
dc.identifier.issn2166-9538
dc.identifier.urihttp://hdl.handle.net/10400.21/12207
dc.language.isoengpt_PT
dc.publisherInstitute of Electrical and Electronics Engineerspt_PT
dc.relation.publisherversionhttps://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9161644pt_PT
dc.subjectGlass insulator stringpt_PT
dc.subjectStubpt_PT
dc.subjectVoltage distributionpt_PT
dc.subjectPollutionpt_PT
dc.titleEffects of broken skirts and pollution on voltage distribution for cap and pin glass insulatorspt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlace8-10 July 2020 - Setúbal, Portugalpt_PT
oaire.citation.endPage35pt_PT
oaire.citation.startPage30pt_PT
oaire.citation.title2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)pt_PT
person.familyNameBarata
person.familyNameLuís
person.givenNameFilipe
person.givenNameRicardo
person.identifier418115
person.identifier.ciencia-id6716-149F-4424
person.identifier.orcid0000-0003-1019-3646
person.identifier.orcid0000-0002-7975-5726
person.identifier.ridH-3022-2016
person.identifier.ridC-8523-2011
person.identifier.scopus-author-id8704704700
person.identifier.scopus-author-id36783299800
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication8af21a8d-4f59-4205-9b41-62e3f735b9e3
relation.isAuthorOfPublication3edfff03-c0ec-4295-9055-0d66bb8fe420
relation.isAuthorOfPublication.latestForDiscovery3edfff03-c0ec-4295-9055-0d66bb8fe420

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Effects_FABarata.pdf
Size:
1.05 MB
Format:
Adobe Portable Document Format