Repository logo
 
Publication

Experimental apparatus for finger ECG biometrics

dc.contributor.authorLourenço, Renato
dc.contributor.authorLeite, Paulo
dc.contributor.authorLourenço, André Ribeiro
dc.contributor.authorSilva, Hugo
dc.contributor.authorFred, Ana
dc.contributor.authorCoutinho, David
dc.date.accessioned2015-09-07T13:32:00Z
dc.date.available2015-09-07T13:32:00Z
dc.date.issued2012
dc.description.abstractCurrent Electrocardiographic (ECG) signal acquisition methods are generally highly intrusive, as they involve the use of pre-gelled electrodes and cabled sensors placed directly on the person, at the chest or limbs level. Moreover, systems that make use of alternative conductive materials to overcome this issue, only provide heart rate information and not the detailed signal itself. We present a comparison and evaluation of two types of dry electrodes as interface with the skin, targeting wearable and low intrusiveness applications, which enable ECG measurement without the need for any apparatus permanently fitted to the individual. In particular, our approach is targeted at ECG biometrics using signals collected at the hand or finger level. A custom differential circuit with virtual ground was also developed for enhanced usability. Our work builds upon the current stateof-the-art in sensoring devices and processing tools, and enables novel data acquisition settings through the use of dry electrodes. Experimental evaluation was performed for Ag/AgCl and Electrolycra materials, and results show that both materials exhibit adequate performance for the intended application.por
dc.identifier.citationLOURENÇO, Renato; [et al] – Experimental apparatus for finger ECG biometrics. In Biodevices, Proceedings of the International Conference on Biomedical Electronics and Devices. Scitepress, 2012. ISBN:978-989-8425-91-1. Pp. 196-200por
dc.identifier.doi10.5220/0003777701960200
dc.identifier.isbn978-989-8425-91-1
dc.identifier.urihttp://hdl.handle.net/10400.21/5082
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherScitepresspor
dc.relationFCT - SFRH/BD/65248/2009
dc.relationFCT - SFRH/PROTEC/49512/2009
dc.subjectDry Ag/AgClpor
dc.subjectElectrolyerapor
dc.subjectECGpor
dc.subjectElectrodespor
dc.subjectHandspor
dc.subjectFingerspor
dc.titleExperimental apparatus for finger ECG biometricspor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.endPage200por
oaire.citation.startPage196por
oaire.citation.titleBiodevices, Proceedings of the International Conference on Biomedical Electronics and Devicespor
person.familyNameSilva
person.givenNameHugo
person.identifier.orcid0000-0003-1585-9099
rcaap.rightsclosedAccesspor
rcaap.typeconferenceObjectpor
relation.isAuthorOfPublication8eb55ac9-195d-4a2e-aa62-eb6e004d5cd1
relation.isAuthorOfPublication.latestForDiscovery8eb55ac9-195d-4a2e-aa62-eb6e004d5cd1

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
EXPERIMENTAL APPARATUS FOR FINGER ECG BIOMETRICS.pdf
Size:
950.24 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: