dc.description.abstractThis paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.por
dc.identifier.citationHENRIQUES, Dulce Franco; NUNES, Lina; BRITO, Jorge de – Development of a penetration test for timber impregnation products for use in old buildings. Construction and Building Materials. ISSN 0950-0618. Vol. 24, N.º 7 (2010), pp. 1095-1100.por
dc.identifier.doi10.5194/nhess-9-1327-2009
dc.identifier.issn0950-0618
dc.identifier.urihttp://hdl.handle.net/10400.21/562
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevier SCI LTDpor
dc.subjectWoodpor
dc.subjectTreatmentspor
dc.subjectOld buildingspor
dc.subjectPenetration testpor
dc.titleDevelopment of a penetration test for timber impregnation products for use in old buildingspor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceOxfordpor
oaire.citation.endPage1100por
oaire.citation.issue7por
oaire.citation.startPage1095por
oaire.citation.titleConstruction and Building Materialspor
oaire.citation.volume24
person.familyNameHenriques
person.familyNameRibeiro Nunes
person.familyNameCaliço Lopes de Brito
person.givenNameDulce
person.givenNameLina Maria
person.givenNameJorge Manuel
person.identifier1979330
person.identifierA-7169-2013
person.identifierA-4299-2008
person.identifier.ciencia-idAD17-A59A-431C
person.identifier.ciencia-id2515-2AE7-A765
person.identifier.ciencia-id921D-3921-8308
person.identifier.orcid0000-0003-1742-147X
person.identifier.orcid0000-0001-6849-3241
person.identifier.orcid0000-0001-6766-2736
person.identifier.ridAAT-6870-2020
person.identifier.scopus-author-id35801069200
person.identifier.scopus-author-id23006201100
person.identifier.scopus-author-id7003285554
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication230e5e95-928d-463c-b955-0ba28478e83f
relation.isAuthorOfPublication0095f7c2-823e-4782-864e-828181a24ec0
relation.isAuthorOfPublicationebc80e57-531a-4fe5-ac87-4d8382b7de2e
relation.isAuthorOfPublication.latestForDiscovery230e5e95-928d-463c-b955-0ba28478e83f

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Development of a penetration test.pdf
Size:
720.83 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: