Repository logo
 
Publication

Aplicação do conceito NZEB a uma habitação e a sua importância num sistema AVAC

dc.contributor.advisorRodrigues, Filipe
dc.contributor.advisorCoelho, Luís
dc.contributor.authorMendes, Jorge Miguel Ferreira Michalli
dc.date.accessioned2021-07-06T17:28:47Z
dc.date.available2021-07-06T17:28:47Z
dc.date.issued2021-04-14
dc.descriptionTrabalho final de mestrado para obtenção do grau de Mestre em Engenharia Mecânicapt_PT
dc.description.abstractA constante preocupação com as alterações climáticas causadas pelo aquecimento global e pelas emissões de Gases de Efeito de Estufa (GEE), aliada à elevada dependência energética da União Europeia (UE) e dos seus Estados Membros (EM), leva à necessidade de promover uma transição energética. A promoção da eficiência energética e a produção e consumo de energia de origem renovável e são os alicerces desta mudança de paradigma. O setor dos edifícios, conjugado com medidas de eficiência energética e medidas de utilização racional de energia, apresenta uma componente essencial no caminho da UE e seus EM para um novo paradigma energético, por isso a UE tem vindo a publicar e a implementar políticas de eficiência energética e produção de energia renovável neste setor. Com a publicação da Diretiva 2010/31/UE relativa ao desempenho energético dos edifícios surgiu o conceito de Nearly Zero Energy Building (NZEB), ou seja, edifícios com um balanço energético quase nulo. Os NZEB são edifícios que apresentam um elevado desempenho energético, não só pelos consumos de energia reduzidos em relação aos edifícios convencionais, mas também por possuírem sistemas de produção/aproveitamento de energia renovável que satisfaçam parte das suas necessidades energéticas. A Diretiva estabelece um quadro bastante geral na implementação dos NZEB, pelo que cabe a cada EM definir de forma quantitativa os requisitos para um edifício ser classificado como NZEB. Em 2019, Portugal publicou as Portarias n.º 42 e 98 que impõem os requisitos mínimos para os NZEB nos edifícios de comércio e serviços e nos edifícios de habitação, respetivamente. O presente trabalho faz uma abordagem específica aos requisitos mínimos para um edifício de habitação ser caracterizado como NZEB, cumprindo com as premissas impostas pela Portaria n.º 98/2019. O caso prático apresentado mostrou que a aplicação de sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC), aliados ao aproveitamento de energia de origem renovável, é o caminho para que os edifícios de habitação sejam classificados como NZEB. Quando comparada com sistemas tradicionais, a bomba de calor ar-água apresenta elevados níveis de eficiência energética (sempre superior à unidade), é capaz de reduzir cerca de 46% das necessidades energéticas, ter um aproveitamento de energia renovável superior a 50% e ainda reduzir até cerca de 80% das emissões de CO2.pt_PT
dc.description.abstractThe constant concern with climate change caused by global warming and Greenhouse Gas (GHG) emissions, combined with the high energy dependence of the European Union (EU) and its Member States (MS), leads to the need to promote an energy transition. The promotion of energy efficiency and the production and consumption of renewable energy and are the foundations of this paradigm shift. The building sector combined with energy efficiency measures and measures of rational use of energy, presents an essential component in the path of the EU and its MS towards a new energy paradigm, which is why the EU has been publishing and implementing efficiency policies energy and renewable energy production in this sector. With the publication of Directive 2010/31/EU related with energy performance of buildings, was introduced the concept of Nearly Zero Energy Building (NZEB), which are buildings with nearly zero energy balance. NZEB are buildings that have a high energy performance, not only for their reduced energy consumption compared to conventional buildings, but also because they have systems for the production/use of renewable energy that satisfy part of their energy needs. The Directive establishes a very general framework in the implementation of NZEB, leaving to each MS to define quantitatively the requirements for a building to be classified as NZEB. In 2019, Portugal published Ordinances No. 42 and 98 that impose the minimum requirements for NZEB in commercial and service buildings and in residential buildings, respectively. This work takes a specific approach to the minimum requirements for a residential building to be characterised as NZEB, complying with the premises imposed by Ordinance No. 98/2019. The practical case presented showed that the application of Heating, Ventilation and Air Conditioning (HVAC) systems, combined with the use of energy from renewable sources, is the way for residential buildings to be classified as NZEB. When compared to traditional systems, the air-water heat pump has high levels of energy efficiency (always higher than the unit), can reduce about 46% of energy needs, has a harnessing of renewable energy over 50% of the energy needs and reducing CO2 emissions by about 80%.pt_PT
dc.description.versionN/Apt_PT
dc.identifier.citationMENDES, Jorge Miguel Ferreira Michalli - Aplicação do conceito NZEB a uma habitação e a sua importância num sistema AVAC. Lisboa: Instituto Superior de Engenharia de Lisboa, 2021. Dissertação de mestrado.pt_PT
dc.identifier.tid202737250
dc.identifier.urihttp://hdl.handle.net/10400.21/13521
dc.language.isoporpt_PT
dc.peerreviewedyespt_PT
dc.publisherInstituto Superior de Engenharia de Lisboapt_PT
dc.subjectNZEBpt_PT
dc.subjectEficiência energéticapt_PT
dc.subjectEnergy efficiencypt_PT
dc.subjectSistemas AVACpt_PT
dc.subjectHVAC Systemspt_PT
dc.subjectEnergia renovávelpt_PT
dc.subjectRenewable energypt_PT
dc.titleAplicação do conceito NZEB a uma habitação e a sua importância num sistema AVACpt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Dissertação.pdf
Size:
4.8 MB
Format:
Adobe Portable Document Format