Name: | Description: | Size: | Format: | |
---|---|---|---|---|
1.03 MB | Adobe PDF |
Advisor(s)
Abstract(s)
This article describes the preliminary results from the new bipolar solid-state Marx generator proposed for Berlin BESSY II injection system, which includes the following pulse specifications: (1) peak voltage of ±8 kV, (2) peak current of 160 A, (3) impedance of 50, (4) frequency ≤10 Hz, (5) width of 350 ns, (6) risetime ≤80 ns, and (7) deviation from “Flat top” ≤ ±1%. The generator is based on SiC metal-oxide-semiconductor field-effect transistors (MOSFETs) in order to allow fast risetime/falltime, where the charging of the main capacitors is from resistive paths. A generator with ten stages, using a dummy load that simulates a kicker magnet, is experimentally tested in order to study the overall performance, and results are presented and discussed.
Description
Keywords
High-speed electronics Particle accelerator magnets Power metal-oxide-semiconductor field-effect transistors (MOSFETS) Pulse power systems Solid-state Marx generator Thyratron replacement
Citation
REDONDO, Luís Manuel; [et al] – Testing of a bipolar solid-state Marx generator for Berlin BESSY II injection kicker system. IEEE Transactions on Plasma Science. ISSN 0093-3813. Vol. 49, N.º 6 (2021), pp. 1936-1940
Publisher
IEEE