Comparing the power losses of power supplies for fast-field cycling nuclear magnetic resonance equipment

dc.contributor.authorLima, Marco
dc.contributor.authorPereira, Bruno
dc.contributor.authorSousa, Duarte M.
dc.contributor.authorRoque, António
dc.contributor.authorMargato, Elmano
dc.date.accessioned2016-12-28T12:53:49Z
dc.date.available2016-12-28T12:53:49Z
dc.date.issued2016-05
dc.description.abstractThe main feature of the Fast-Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) power supplies is to drive a controlled current fulfilling the requirements of this technique. This feature allows fast switching the current of the FFC magnet and performing accurate and repetitive current cycles. When designing this equipment the power losses is not a fundamental parameter of the optimization process but are estimated in order to validate the topology of the final solution giving that the efficiency of the power solution influences the power consumption, and therefore the operational costs, which should be minimized. Under this context, from the power efficiency viewpoint, the power losses of two possible solutions are compared and discussed in this paper. Typical FFC current cycles are used as reference in order to balance the pros and cons of both solutions.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationLIMA, Marco; [et al] - Comparing the Power Losses of Power Supplies for Fast-Field Cycling Nuclear Magnetic Resonance Equipment. EEEJ. [Em linha]. Vol. 1, N.º 3 (2016), pp. 139-144. [Consult. 27-12-2016]. Disponível na internet <URL: http://www.aedie.org/papers/15016-lima.pdf>. eISSN 2227-3344.pt_PT
dc.identifier.other2227-3344
dc.identifier.urihttp://hdl.handle.net/10400.21/6678
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherAcademic Society of Science, Engineering and Technologypt_PT
dc.relation.publisherversionhttp://www.aedie.org/papers/15016-lima.pdfpt_PT
dc.subjectPower supplypt_PT
dc.subjectPower lossespt_PT
dc.subjectFast-Field Cyclingpt_PT
dc.subjectDC-DC conversionpt_PT
dc.titleComparing the power losses of power supplies for fast-field cycling nuclear magnetic resonance equipmentpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage144pt_PT
oaire.citation.issue3pt_PT
oaire.citation.startPage139pt_PT
oaire.citation.titleEnergy and Environmental Engineering Journalpt_PT
oaire.citation.volume1pt_PT
person.familyNameMargato
person.givenNameElmano
person.identifier.ciencia-id2F12-3295-B091
person.identifier.orcid0000-0002-8601-9145
person.identifier.scopus-author-id6505972972
rcaap.rightsrestrictedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication9f983bef-f0ef-4660-b6e9-e9beebaf6acc
relation.isAuthorOfPublication.latestForDiscovery9f983bef-f0ef-4660-b6e9-e9beebaf6acc

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Comparing_EMargato_ADEEEA.pdf
Size:
1015.16 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: