Repository logo
 
Publication

ECG simulator with configurable skin-electrode impedance and artifacts emulation

dc.contributor.authorAlmeida, Daniel
dc.contributor.authorCosta, João
dc.contributor.authorLourenço, André
dc.date.accessioned2021-10-21T08:57:35Z
dc.date.available2021-10-21T08:57:35Z
dc.date.issued2021-10-08
dc.description.abstractElectrocardiograms (ECG) recorded from everyday objects, such as wearables, fitness machines or smart steering wheels are becoming increasingly common. Applications are diverse and include health monitoring, athletic performance optimization, identification, authentication, and entertainment. In this study we report the design and implementation of an innovative ECG simulator, providing simulation of signal related artifacts and a dynamically adjustable skin-electrode interface model. The ECG simulator includes a unique combination of features: emulation of time dependent skinelectrode impedance, adjustable differential and common-mode interference, generation of lead-off events and analog front-end output digitalization. The skin-electrode capacitance range is 1 nF-255 nF and the resistance span is 4 kΩ-996 kΩ. System’s functionality is demonstrated using a commercially available ECG front-end. The simulated SNR degradation introduced by the ECG simulator is under 0.1 dB. Results show that the skin-electrode interface can have a significant impact in the acquired waveforms. Impedance electrode imbalance, specifically of the resistive component, can generate artifacts which can be misinterpreted has arrhythmias. The proposed device can be useful for hardware and software ECG development and for training physicians and nurses to readily recognize skin-electrode impedance related artifacts.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationALMEIDA, Daniel; COSTA, João; LOURENÇO, André – ECG simulator with configurable skin-electrode impedance and artifacts emulation. Biomedical Physics & Engineering Express. eISSN 2057-1976. Vol. 7, N.º 6 (2021), pp. 1-16pt_PT
dc.identifier.doi10.1088/2057-1976/ac2b4ept_PT
dc.identifier.eissn2057-1976
dc.identifier.urihttp://hdl.handle.net/10400.21/13911
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherIOP Publishingpt_PT
dc.subjectElectrocardiographypt_PT
dc.subjectSkin-electrode impedancept_PT
dc.subjectECG front-endpt_PT
dc.subjectDry electrodespt_PT
dc.subjectECG emulationpt_PT
dc.subjectECG simulatorpt_PT
dc.titleECG simulator with configurable skin-electrode impedance and artifacts emulationpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage16pt_PT
oaire.citation.issue6pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.titleBiomedical Physics & Engineering Expresspt_PT
oaire.citation.volume7pt_PT
person.familyNameGonçalves Pita Santos de Almeida
person.familyNameCosta
person.familyNameLourenço
person.givenNameDaniel
person.givenNameJoão
person.givenNameAndré
person.identifierhttps://scholar.google.com/citations?user=FHi2JLIAAAAJ&hl=pt-PT
person.identifier.ciencia-idBC13-279E-D2D7
person.identifier.ciencia-id2314-A300-7C09
person.identifier.orcid0000-0003-2228-2507
person.identifier.orcid0000-0002-8058-3685
person.identifier.orcid0000-0001-8935-9578
person.identifier.scopus-author-id35810047500
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication1cc87c74-47de-46e0-a587-c2de0847a41d
relation.isAuthorOfPublicationa64d2f5a-2af3-4d5b-adb4-7de0edad0f84
relation.isAuthorOfPublicationcbc6b0dc-187b-4f88-a8b3-52b4721df057
relation.isAuthorOfPublication.latestForDiscoverycbc6b0dc-187b-4f88-a8b3-52b4721df057

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ECG simulator_ALourenco.pdf
Size:
3.13 MB
Format:
Adobe Portable Document Format