Repository logo
 
Publication

Comparison between 3D laser scanning and computed tomography on the modelling of head surface

dc.contributor.authorSousa, E.
dc.contributor.authorVieira, L.
dc.contributor.authorCosta, D. M. S.
dc.contributor.authorCosta, D. C.
dc.contributor.authorParafita, R.
dc.contributor.authorLoja, Amélia
dc.date.accessioned2017-06-09T10:39:14Z
dc.date.available2017-06-09T10:39:14Z
dc.date.issued2017-04
dc.descriptionEste trabalho foi financiado pelo Concurso Anual para Projetos de Investigação, Desenvolvimento, Inovação e Criação Artística (IDI&CA) 2016 do Instituto Politécnico de Lisboa. Código de referência IPL/2016/SoftImob_ISEL
dc.description.abstractThe measurement of people physical parameters and proportions constitutes an importante field of science, the anthropometry, since it is related to the characterization of the human size and constitution; it allows improving the design and sizing of systems and devices to human use. To enable these measurements, different direct and indirect methodologies may be used depending on the particular aim of a specific study and on the eventual availability of data sources that can be used also for this purpose. Because of this relevance, the present work intends to assess the influence of diferente acquisition and reconstruction methods in the modelling of a 3D head surface. In order to assess the significance of the differences between acquisition and reconstruction methods a set of measurements between several anatomic references of a physical phantom were carried out. Statistical evaluation using the Friedman test for non-parametrical pared samples was considered. We found, so far, no statistically significant differences between the several methods considered for acquisition and reconstruction.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationSOUSA, E.; [et al]. – Comparison between 3D laser scanning and computed tomography on the modelling of head surfasse. In 3rd International Conference on Numerical and Symbolic Computation – SYMCOMP 2017. Guimarães, Portugal. ECCOMAS – European Community on Computational Methods in Applied Sciences, 2017. Pp. 119-128.pt_PT
dc.identifier.isbn978‐989‐99410‐3‐8
dc.identifier.urihttp://hdl.handle.net/10400.21/7178
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherECCOMAS – European Community on Computational Methods in Applied Sciencespt_PT
dc.relationProjeto financiado no âmbito do Concurso de Projetos de Investigação, Desenvolvimento, Inovação & Criação Artística (IDI&CA) financiados pelo Instituto Politécnico de Lisboa. IPL/2016/SoftImob_ISEL
dc.relation.publisherversionhttp://www.eccomas.org/cvdata/cntr1/spc10/dtos/img/mdia/symcomp2017-proceedings-160517.pdfpt_PT
dc.subject3D laser scanningpt_PT
dc.subjectComputed tomographypt_PT
dc.subjectModelling of head surfacept_PT
dc.subjectStatistical assessment of the modelspt_PT
dc.titleComparison between 3D laser scanning and computed tomography on the modelling of head surfacept_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.endPage128pt_PT
oaire.citation.startPage119pt_PT
person.familyNameLoja
person.givenNameAmélia
person.identifier.ciencia-idA016-59D1-2D00
person.identifier.orcid0000-0002-4452-5840
person.identifier.ridI-7513-2015
person.identifier.scopus-author-id15741348500
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication9f43a546-1632-49c5-bd44-94aac2d7b648
relation.isAuthorOfPublication.latestForDiscovery9f43a546-1632-49c5-bd44-94aac2d7b648

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Comparison_ESousa_ADEM.pdf
Size:
31.36 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: