Repository logo
 
Publication

Lockdown measures for COVID-19 outbreak and variation in physical activity in patients with heart failure and cardiac implantable devices

dc.contributor.authorSilva Cunha, Pedro
dc.contributor.authorLaranjo, Sérgio
dc.contributor.authorLourenço, André
dc.contributor.authorRodrigues, Lourenço
dc.contributor.authorCardoso, Isabel
dc.contributor.authorPortugal, Guilherme
dc.contributor.authorValente, Bruno
dc.contributor.authorDelgado, Ana Sofia
dc.contributor.authorFerreira, Rui Cruz
dc.contributor.authorAbreu, Ana
dc.contributor.authorOliveira, Mario
dc.date.accessioned2022-01-28T10:59:48Z
dc.date.available2022-01-28T10:59:48Z
dc.date.issued2021-12
dc.description.abstractAims: The present study analysed the patterns of physical activity pre-, during and post-lockdown measures for COVID-19 pandemic in patients with chronic heart failure (CHF) and cardiac implantable electronic devices (CIED) under remote monitoring (RM), and assessed the physical activity patterns during these periods. Methods: The raw data from 95 patients with CHF (age 67,7 +/- 15,1 years, 71,5% male) corresponding to 2238 RM transmissions of the Medtronic Carelink (TM) network platform was obtained. The physical exercise profiles and the impact of the lockdown measures on the physical behaviour during and after the measures were analysed. According to the level of activity duration in the pre-lockdown, lockdown and post-lockdown periods, the patterns of behaviour were identified (non-recoverees, incomplete recoverees, recoverees and full-recoverees). Conclusion: RM of CHF patients with CIED using the Carelink (TM) network is useful for close follow-up and identification of heart failure risk status variations. After relieving the confinement measures there were two groups of patients that did not recover the previous physical activity levels. Physical inactivity in patients with CHF can have a significant impact on outcomes.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationCUNHA, Pedro Silva; [et al] – Lockdown measures for COVID-19 outbreak and variation in physical activity in patients with heart failure and cardiac implantable devices. IJC Heart & Vasculature. eISSN 2352-9067. Vol. 37 (2021), pp. 1-8.pt_PT
dc.identifier.doi10.1016/j.ijcha.2021.100906pt_PT
dc.identifier.eissn2352-9067
dc.identifier.urihttp://hdl.handle.net/10400.21/14214
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S2352906721001949?via%3Dihubpt_PT
dc.subjectRemote monitoringpt_PT
dc.subjectCarelink (TM) networkpt_PT
dc.subjectHeart failurept_PT
dc.subjectPhysical activitypt_PT
dc.titleLockdown measures for COVID-19 outbreak and variation in physical activity in patients with heart failure and cardiac implantable devicespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage8pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.titleIJC Heart & Vasculaturept_PT
oaire.citation.volume37pt_PT
person.familyNameSilva Cunha
person.familyNameLourenço
person.familyNameMartins Oliveira
person.givenNamePedro
person.givenNameAndré
person.givenNameMario Joao
person.identifier1235667
person.identifier.ciencia-id4716-747F-D64E
person.identifier.ciencia-id2312-2190-19B2
person.identifier.orcid0000-0001-9465-634X
person.identifier.orcid0000-0001-8935-9578
person.identifier.orcid0000-0002-8371-8354
person.identifier.scopus-author-id6504508117
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication20119320-1ab8-4396-abcf-d92d482e3a46
relation.isAuthorOfPublicationcbc6b0dc-187b-4f88-a8b3-52b4721df057
relation.isAuthorOfPublicatione8b6386a-b581-47ad-b8b3-52baf20342ef
relation.isAuthorOfPublication.latestForDiscoverycbc6b0dc-187b-4f88-a8b3-52b4721df057

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Lockdown_ALourenco.pdf
Size:
1.58 MB
Format:
Adobe Portable Document Format