dc.description.abstract | A transient analysis for two full-power converter wind turbines equipped with a permanent magnet synchronous generator is studied in this article, taking into consideration, as a new contribution to earlier studies, a pitch control malfunction. The two full-power converters considered are, respectively, a two-level and a multi-level converter. Moreover, a novel control strategy based on fractional-order controllers for wind turbines is studied. Simulation results are presented; conclusions are in favor of the novel control strategy, improving the quality of the energy injected into the electric grid. | por |
dc.identifier.citation | Melicio R, Mendes V M F, Catalão J P S.A Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters: Proportional Integral Versus Fractional-order Controllers. Electric Power Components and Systems. 2010; 38 (4): 387-406. | por |
dc.identifier.issn | 1532-5008 | |
dc.identifier.uri | http://hdl.handle.net/10400.21/707 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Taylor & Francis INC | por |
dc.relation.ispartofseries | 4; | |
dc.subject | Fractional-order controller | por |
dc.subject | Pitch control malfunction | por |
dc.subject | Power converters | por |
dc.subject | Power quality | por |
dc.subject | Wind turbines | por |
dc.title | A Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters: Proportional Integral Versus Fractional-order Controllers | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.conferencePlace | Philadelphia | por |
oaire.citation.endPage | 406 | por |
oaire.citation.issue | 38 | por |
oaire.citation.startPage | 387 | por |
oaire.citation.title | Electric Power Components and Systems | por |
person.familyName | Mendes | |
person.givenName | Victor | |
person.identifier.orcid | 0000-0002-4599-477X | |
person.identifier.rid | D-2332-2012 | |
person.identifier.scopus-author-id | 55138675600 | |
rcaap.rights | restrictedAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | a86b9291-f23c-4f09-83d7-9ee691696705 | |
relation.isAuthorOfPublication.latestForDiscovery | a86b9291-f23c-4f09-83d7-9ee691696705 |
Files
Original bundle
1 - 2 of 2
No Thumbnail Available
- Name:
- A Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters_rep.pdf
- Size:
- 50.53 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- A pitch control malfunction analysis.pdf
- Size:
- 827.76 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: