Repository logo
 
Publication

A Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters: Proportional Integral Versus Fractional-order Controllers

dc.contributor.authorMelicio, R.
dc.contributor.authorMendes, Victor
dc.contributor.authorCatalão, João Paulo da Silva
dc.date.accessioned2011-11-28T19:51:14Z
dc.date.available2011-11-28T19:51:14Z
dc.date.issued2010
dc.description.abstractA transient analysis for two full-power converter wind turbines equipped with a permanent magnet synchronous generator is studied in this article, taking into consideration, as a new contribution to earlier studies, a pitch control malfunction. The two full-power converters considered are, respectively, a two-level and a multi-level converter. Moreover, a novel control strategy based on fractional-order controllers for wind turbines is studied. Simulation results are presented; conclusions are in favor of the novel control strategy, improving the quality of the energy injected into the electric grid.por
dc.identifier.citationMelicio R, Mendes V M F, Catalão J P S.A Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters: Proportional Integral Versus Fractional-order Controllers. Electric Power Components and Systems. 2010; 38 (4): 387-406.por
dc.identifier.issn1532-5008
dc.identifier.urihttp://hdl.handle.net/10400.21/707
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor & Francis INCpor
dc.relation.ispartofseries4;
dc.subjectFractional-order controllerpor
dc.subjectPitch control malfunctionpor
dc.subjectPower converterspor
dc.subjectPower qualitypor
dc.subjectWind turbinespor
dc.titleA Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters: Proportional Integral Versus Fractional-order Controllerspor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlacePhiladelphiapor
oaire.citation.endPage406por
oaire.citation.issue38por
oaire.citation.startPage387por
oaire.citation.titleElectric Power Components and Systemspor
person.familyNameMendes
person.givenNameVictor
person.identifier.orcid0000-0002-4599-477X
person.identifier.ridD-2332-2012
person.identifier.scopus-author-id55138675600
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublicationa86b9291-f23c-4f09-83d7-9ee691696705
relation.isAuthorOfPublication.latestForDiscoverya86b9291-f23c-4f09-83d7-9ee691696705

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
A Pitch Control Malfunction Analysis for Wind Turbines with Permanent Magnet Synchronous Generator and Full-power Converters_rep.pdf
Size:
50.53 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
A pitch control malfunction analysis.pdf
Size:
827.76 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: