Publication
Off-the-person electrocardiography: performance assessment and clinical correlation
dc.contributor.author | Silva, Hugo Plácido da | |
dc.contributor.author | Carreiras, Carlos | |
dc.contributor.author | Lourenço, André Ribeiro | |
dc.contributor.author | Fred, Ana | |
dc.contributor.author | Neves, Rui César das | |
dc.contributor.author | Ferreira, Rui | |
dc.date.accessioned | 2016-04-27T17:17:23Z | |
dc.date.available | 2016-04-27T17:17:23Z | |
dc.date.issued | 2015-04-01 | |
dc.description.abstract | Previous work by our group introduced a novel concept and sensor design for “off-the-person” ECG, for which evidence on how it compares against standard clinical-grade equipment has been largely missing. Our objectives with this work are to characterise the off-the-person approach in light of the current ECG systems landscape, and assess how the signals acquired using this simplified setup compare with clinical-grade recordings. Empirical tests have been performed with real-world data collected from a population of 38 control subjects, to analyze the correlation between both approaches. Results show off-the-person data to be correlated with clinical-grade data, demonstrating the viability of this approach to potentially extend preventive medicine practices by enabling the integration of ECG monitoring into multiple dimensions of people’s everyday lives. © 2015, IUPESM and Springer-Verlag Berlin Heidelberg. | pt_PT |
dc.identifier.citation | SILVA, Hugo Plácido da; [et al] - Off-the-person electrocardiography: performance assessment and clinical correlation. Health and Technology. ISSN 2190-7188. Vol. 4, N.º 4 (2015), pp. 309-318 | pt_PT |
dc.identifier.doi | 10.1007/s12553-015-0098-y | pt_PT |
dc.identifier.issn | 2190-7188 | |
dc.identifier.issn | 2190-7196 | |
dc.identifier.uri | http://hdl.handle.net/10400.21/6105 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Springer Verlag | pt_PT |
dc.relation | Learning from Sequences (LearningS) | |
dc.subject | Electrocardiography | pt_PT |
dc.subject | Off-the-person | pt_PT |
dc.subject | Pervasive health | pt_PT |
dc.subject | Taxonomy | pt_PT |
dc.title | Off-the-person electrocardiography: performance assessment and clinical correlation | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.awardTitle | Learning from Sequences (LearningS) | |
oaire.awardURI | info:eu-repo/grantAgreement/FCT/3599-PPCDT/PTDC%2FEEI-SII%2F2312%2F2012/PT | |
oaire.awardURI | info:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F65248%2F2009/PT | |
oaire.citation.endPage | 318 | pt_PT |
oaire.citation.issue | 4 | pt_PT |
oaire.citation.startPage | 309 | pt_PT |
oaire.citation.title | Health and Technology | pt_PT |
oaire.citation.volume | 4 | pt_PT |
oaire.fundingStream | 3599-PPCDT | |
oaire.fundingStream | SFRH | |
project.funder.identifier | http://doi.org/10.13039/501100001871 | |
project.funder.identifier | http://doi.org/10.13039/501100001871 | |
project.funder.name | Fundação para a Ciência e a Tecnologia | |
project.funder.name | Fundação para a Ciência e a Tecnologia | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isProjectOfPublication | 48934697-f0f8-4b61-930b-e6ee339e6396 | |
relation.isProjectOfPublication | d7beb08c-39ed-4ac3-8616-b226ef777c17 | |
relation.isProjectOfPublication.latestForDiscovery | 48934697-f0f8-4b61-930b-e6ee339e6396 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Off-the-person electrocardiography - performance assessment and clinical correlation.pdf
- Size:
- 1.07 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: