Repository logo
 
Publication

Aplicação para análise de cortes transaxiais dos corpos estriados em imagens obtidas por [123|]FP-CIT SPECT

dc.contributor.advisorJorge, Pedro Miguel Torres Mendes
dc.contributor.advisorFigueiredo, Sérgio
dc.contributor.authorElias, Maria Madalena Penaforte Pirão
dc.date.accessioned2018-04-06T19:33:20Z
dc.date.available2018-04-06T19:33:20Z
dc.date.issued2017-11-29
dc.descriptionTrabalho final de mestrado para obtenção do grau de mestre em Engenharia Biomédicapt_PT
dc.description.abstractAtualmente, a Cintigrafia Cerebral com DaTSCANTM SPECT é uma ferramenta que permite o auxílio no diagnóstico de Síndromes Parkinsonianos. É um exame da Medicina Nuclear (MN) cujas imagens são analisadas, na sua maioria, por inspeção visual de clínicos experientes. Em casos duvidosos, de forma a auxiliar o diagnóstico, existem aplicações comercialmente disponíveis que permitem a quantificação destes estudos a partir da segmentação do tecido estriado cerebral, maioritariamente de forma semi-automática com ajustes manuais por parte de um operador, cuja variabilidade intra e interoperador pode influenciar a quantificação destes estudos e, em última análise, o diagnóstico clínico. De forma a colmatar este problema, o objetivo deste trabalho foi construir uma aplicação automática em linguagem de programação Python® para a análise de cortes transaxiais dos corpos estriados em imagens obtidas por [123I]FP-CIT SPECT, provenientes do serviço de MN do Hospital Particular de Almada (HPA), constituído por 68 pacientes, com e sem patologia. De modo a comparar os rácios de captação específica obtidos para os corpos estriados, desenvolveu-se ainda uma aplicação semi-automática com ajustes manuais por parte de um operador. Finalmente os resultados obtidos foram comparados com a aplicação DaTSCAN V4, da General Electric Healthcare. Verificou-se que a aplicação automática desenvolvida consegue discriminar com sucesso os pacientes sem patologia dos pacientes com patologia nos rácios A (Corpos estriados/Occipital) (AUC=0,85, sensibilidade=80%, especificidade=90%), B (Corpo estriado esquerdo/Occipital) (AUC=0,82, sensibilidade=84%, especificidade=80%) e C (Corpo estriado direito/Occipital) (AUC=0,85, sensibilidade=80%, especificidade=90%), com forte correlação com os métodos semi-automáticos (DaTSCANV4 e aplicação desenvolvida). Contudo, esta correlação não se observou para o rácio D (Corpo estriado esquerdo/Corpo estriado direito) (AUC=0,63, sensibilidade=56%, especificidade=70%). Verificou-se também a existência de variabilidade intra e interoperador nos métodos semi-automáticos, contrariamente à aplicação automática desenvolvida. A implementação deste método para segmentação e quantificação de cortes transaxiais dos corpos estriados em imagens obtidas por [123I]FP-CIT SPECT demonstrou resultados tendencialmente promissores, cuja potencialidade de aplicação pode complementar diferencialmente a análise visual, ainda que careça de otimização e validação futura.pt_PT
dc.description.abstractCurrently, a Brain SPECT with DaTSCANTM is a tool that helps diagnose of Parkinsonian Syndromes. It is an imaging technique of Nuclear Medicine, whose images are mostly analized by visual interpretation from experienced observers. In doubtful cases, in order to help the diagnosis, there are commercial software packages that allow the quantification of these studies from the segmentation of the striatum, mostly by semi-quantitative measures with manual adjustments from an operator, whose intra and inter-operator variability can influence the quantification of these studies and clinical diagnosis. In order to overcome this problem, the main goal of this project is to construct an automatic application in Python for the analysis of transaxial slices of the striatum in images obtained by [123I] FP-CIT SPECT from nuclear medicine department of the Hospital Particular de Almada, with 68 patients with and without pathology. In order to compare the specific uptake ratios for the striatum, a semi-automatic application was developed with manual adjustments by an operator. Finally the obtained results were compared with the DaTSCAN V4 application, from General Electric Healthcare. It was possible to verify that the automatic application developed successfully discriminates the healthy patients of the pathological ones in the ratios A (Striatum/Occipital) (AUC=0.85, sensitivity=80%, specificity=90%), ratio B (Left Striatum/Occipital) (AUC=0.82, sensitivity=84%, specificity=80%), and ratio C (Right Striatum/Occipital) (AUC=0.85, sensitivity=80%, specificity=90%), with a strong correlation with semi-automatic methods (DaTSCAN V4 and developed application). However, this correlation was not observed for the ratio D (Left Striatum/Right Striatum) (AUC=0.63, sensitivity=56%, specificity=70%). There was also an existence of intra- and inter-operator variability in semi-automatic methods, contrary to the automatic application developed. The implementation of this method for segmentation and quantification of transaxial slices of the striatum in images obtained by [123I]FP-CIT SPECT demonstrated promising results, whose potentiality of application can complement the visual analysis differently, even though it lacks future optimization and validation.en
dc.description.versionN/Apt_PT
dc.identifier.citationELIAS, Maria Madalena Penaforte Pirão - Aplicação para análise de cortes transaxiais dos corpos estriados em imagens obtidas por [123|]FP-CIT SPECT. Lisboa: Instituto Superior de Engenharia de Lisboa - Escola Superior de Tecnologia da Saúde de Lisboa, 2017. Dissertação de mestrado.pt_PT
dc.identifier.tid201896435
dc.identifier.urihttp://hdl.handle.net/10400.21/8369
dc.language.isoporpt_PT
dc.peerreviewedyespt_PT
dc.publisherInstituto Superior de Engenharia de Lisboa - Escola Superior de Tecnologia da Saúde de Lisboapt_PT
dc.subjectSegmentação de imagempt_PT
dc.subjectImage segmentationen
dc.subjectQuantificaçãopt_PT
dc.subjectQuantificationen
dc.subjectRácios de captação específicapt_PT
dc.subjectSpecific uptake ratiosen
dc.subjectAnálise de imagem automáticapt_PT
dc.subjectAutomated image analysisen
dc.subjectDaTSCANTMen
dc.titleAplicação para análise de cortes transaxiais dos corpos estriados em imagens obtidas por [123|]FP-CIT SPECTpt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Dissertação.pdf
Size:
6.57 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: