Repository logo
 
Publication

Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images

dc.contributor.authorElias, Maria
dc.contributor.authorJorge, Pedro
dc.contributor.authorFigueiredo, Sérgio
dc.contributor.authorOliveira, Luís
dc.contributor.authorPereira, Edgar L.
dc.date.accessioned2020-04-23T14:56:35Z
dc.date.available2020-04-23T14:56:35Z
dc.date.issued2019-04-18
dc.description.abstractThe aim of this work was to implement an automatic application (AA) for the quantification of the striatum transaxial slices based on [I-123]FP-CIT SPECT (Single Photon Emission Tomography) images. A sample of 68 subjects with and without pathology was collected from the nuclear medicine department of the Hospital Particular de Almada. In order to compare the striatum specific uptake ratios (SUR), a semi-automatic application (SAA) was also developed allowing manual adjustments by a specialist operator. The obtained results were compared with the DaTSCAN (R) V4 application, from General Electric Healthcare. The experimental results based on SUR demonstrate that the AA can successfully discriminate the healthy patients from the pathological subjects. Additionally, a strong correlation was verified between the AA and the semi-automatic methods (DaTSCAN (R) V4 and the SAA). These methods also evidence intra and inter-operator variability, suppressed by the AA. The proposed methodology for segmentation and quantification of the striatum transaxial images obtained by [I-123]FP-CIT SPECT demonstrated that the developed application can accurately complement the visual analysis, requiring future optimization.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationELIAS, Maria; [et al] – Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images. In 2019 6th IEEE Portuguese Meeting on Bioengineering (ENBENG). Lisbon, Portugal: IEEE, 2019. ISBN 978-1-5386-8507-5. Pp. 1-4pt_PT
dc.identifier.doi10.1109/ENBENG.2019.8692477pt_PT
dc.identifier.isbn978-1-5386-8507-5
dc.identifier.issn978-1-5386-8506-8
dc.identifier.urihttp://hdl.handle.net/10400.21/11507
dc.language.isoengpt_PT
dc.publisherInstitute of Electrical and Electronics Engineerspt_PT
dc.relation.publisherversionhttps://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8692477&tag=1pt_PT
dc.subjectNuclear medicinept_PT
dc.subjectSingle photon emission computed tomographypt_PT
dc.subjectAutomatic applicationpt_PT
dc.subjectSpecific uptake ratiopt_PT
dc.subjectStriatum transaxial imagespt_PT
dc.subjectDaTSCAN V4 applicationpt_PT
dc.titleAutomatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT imagespt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlace22-23 Feb. 2019 - Lisbon, Portugalpt_PT
oaire.citation.endPage4pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.title2019 6th IEEE Portuguese Meeting on Bioengineering (ENBENG)pt_PT
person.identifier.ciencia-idF61C-F1EB-88B8
person.identifier.orcid0000-0003-1597-410X
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublicationaaf73613-1657-426b-bfad-61538719c7a1
relation.isAuthorOfPublication.latestForDiscoveryaaf73613-1657-426b-bfad-61538719c7a1

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Automatica_PMJorge.pdf
Size:
774.28 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: