Repository logo
 
Publication

Evaluation of the amount of nanoparticles emitted in welding fume from stainless steel using different shielding gases

dc.contributor.authorPacheco, Rita
dc.contributor.authorGomes, João
dc.contributor.authorMiranda, R.
dc.contributor.authorQuintino, M. L.
dc.date.accessioned2017-11-09T14:50:15Z
dc.date.available2017-11-09T14:50:15Z
dc.date.issued2017
dc.description.abstractThe primary objective of this study was to correlate the emission of macro and nanoparticles released during the process of metal inert gas/metal active gas (MIG/MAG) of stainless steel with different gas mixtures. Using different gas mixtures with different heat inputs, it was possible to determine fume formation rates and surface areas of nanoparticles with alveolar lung deposition capacity. It was found, how the various transfer modes and the type of gas protection, in particular, the percentage of active elements in the in the chemical composition of the gas, affect the amount of fumes generated and also the generation of nanoparticles with a high capacity of deposition. The spray transfer mode always shows higher values of nanoparticles surface area, unlike the fume formation rates. Among the tested mixtures 82%Ar+18%CO2 generates higher emissions of nanoparticles as well as fume formation rates.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationPACHECO, R. P.; [et al] - Evaluation of the amount of nanoparticles emitted in welding fume from stainless steel using different shielding gases. Inhalation Toxicology. ISSN 0895-8378. Vol. 29, N.º 6 (2017), pp. 282-289pt_PT
dc.identifier.doi10.1080/08958378.2017.1358778pt_PT
dc.identifier.issn0895-8378
dc.identifier.issn1091-7691
dc.identifier.urihttp://hdl.handle.net/10400.21/7470
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherTaylor & Francispt_PT
dc.subjectFusion weldingpt_PT
dc.subjectWelding fumept_PT
dc.subjectMetal inert gaspt_PT
dc.subjectMetal active gaspt_PT
dc.subjectNanoparticlespt_PT
dc.subjectShielding gasespt_PT
dc.subjectTransfer modespt_PT
dc.titleEvaluation of the amount of nanoparticles emitted in welding fume from stainless steel using different shielding gasespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage289pt_PT
oaire.citation.issue6pt_PT
oaire.citation.startPage282pt_PT
oaire.citation.titleInhalation Toxicologypt_PT
oaire.citation.volume29pt_PT
person.familyNamePacheco
person.familyNameGomes
person.familyNameMiranda
person.givenNameRita
person.givenNameJoão
person.givenNameR.
person.identifier1022927
person.identifier60203
person.identifier.ciencia-id9F13-D310-B5A3
person.identifier.ciencia-id0212-E6D6-566C
person.identifier.orcid0000-0001-5192-3006
person.identifier.orcid0000-0003-2579-6669
person.identifier.orcid0000-0002-6551-9677
person.identifier.ridC-3062-2012
person.identifier.ridD-3330-2011
person.identifier.scopus-author-id8853708300
person.identifier.scopus-author-id56113031900
person.identifier.scopus-author-id26031522600
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationd6907c0a-3f8f-431c-acf2-0b257692f0d4
relation.isAuthorOfPublicatione44cd72e-bcbb-4612-a274-60cb1915bc0c
relation.isAuthorOfPublicationb729cc56-92ef-4b26-80cf-f8692206c27d
relation.isAuthorOfPublication.latestForDiscoveryd6907c0a-3f8f-431c-acf2-0b257692f0d4

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Evaluation_JGomes_ADEQ.pdf
Size:
3.76 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: