Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.21/7667
Título: Output Voltage Quality Evaluation of Stand-alone Four-Leg Inverters Using Linear and Non-Linear Controllers
Autor: Luís, Ricardo
Silva, José Fernando
Quadrado, José Carlos
Palavras-chave: Stand-alone four-leg inverter
Non-linear voltage vector modulator
Voltage waveform quality
Data: Abr-2017
Editora: MDPI
Citação: LUÍS, Ricardo; SILVA, José Fernando; QUADRADO, José Carlos - Output Voltage Quality Evaluation of Stand-alone Four-Leg Inverters Using Linear and Non-Linear Controllers. Energies. ISSN 1996-1073. Vol. 10, N. º4, (2017), pp. 1-20
Resumo: This paper presents the design and experimental voltage quality evaluation of controllers for the output voltages of 3-phase four-leg voltage source inverters. These inverters are needed in stand-alone power systems to supply linear and non-linear, balanced or unbalanced loads with constant RMS value voltages at fixed frequency. Comparisons include closed loop outer voltage controllers based on predictive, sliding mode and decoupled proportional-integral controllers in dqo synchronous space, fitted with an inner hysteretic current loop vector controller in alpha beta gamma space. The 3-phase four-leg VSI output voltages waveform quality is analysed under unbalanced and non-linear loads.
Peer review: yes
URI: http://hdl.handle.net/10400.21/7667
DOI: 10.3390/en10040504
ISSN: 1996-1073
Versão do Editor: file:///C:/Users/utilizador2/Downloads/energies-10-00504.pdf
Aparece nas colecções:ISEL - Eng. Electrotécn. - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Output Voltage Quality_R.Luís_ADEEEA.pdf5,97 MBAdobe PDFVer/Abrir    Acesso Restrito. Solicitar cópia ao autor!


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.