Título: Blurred digital mammography images: an analysis of technical recall and observer detection performance
Autor: Ma, Wang Kei
Borgen, Rita
Kelly, Judith
Millington, Sara
Hilton, Beverley
Aspin, Rob
Lança, Carla Costa
Hogg, Peter
Palavras-chave: Breast
Breast neoplasms
Female
Humans
Mammography
Observer variation
Reproducibility of results
United Kingdom
Data: Mar-2017
Editora: British Institute of Radiology
Citação: Ma WK, Borgen R, Kelly J, Millington S, Hilton B, Lança C, et al. Blurred digital mammography images: an analysis of technical recall and observer detection performance. Br J Radiol. 2017;90(1071):ID20160271.
Resumo: Objective - Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. Methods - 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. Results - The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. Conclusion - According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur.
Peer review: yes
URI: http://hdl.handle.net/10400.21/7331
DOI: 10.1259/bjr.20160271
Versão do Editor: http://www.birpublications.org/doi/abs/10.1259/bjr.20160271
Aparece nas colecções:ESTeSL - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Blurred digital mammography images.pdf1,2 MBAdobe PDFVer/Abrir    Acesso Restrito. Solicitar cópia ao autor!


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.