Título: Optimising protocol of acquisition and post-processing procedures in the assessment of coronary artery disease by computed tomography
Autor: Ribeiro, Margarida
Gonçalves, Nuno Caldeira
Bate, Inês Baião
O'Neill, João Goyri
Maurício, J. Cruz
Palavras-chave: Computed tomography
Medical clinics
Computational bio-imaging and visualisation
Data processing and analysis
Medical imaging
Visualisation
Data: 2015
Editora: Taylor & Francis
Citação: Ribeiro MM, Gonçalves NC, Bate IB, O'Neill JG, Maurício JC. Optimising protocol of acquisition and post-processing procedures in the assessment of coronary artery disease by computed tomography. Comput Methods Biomech Biomed Eng. 2015;3(2):91-100.
Resumo: Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semiautomated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developingCADto be predicted will be presented. A64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
Peer review: yes
URI: http://hdl.handle.net/10400.21/4378
DOI: 10.1080/21681163.2014.895680
Versão do Editor: http://www.tandfonline.com/doi/abs/10.1080/21681163.2014.895680
Aparece nas colecções:ESTeSL - Artigos



FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.